Project Details
Description
Principal Investigators/Program Directors (Last, First, Middle): Liang, Jerome Z.
Project Summary/Abstract
According to American Cancer Society statistics, lung cancer is the leading cause of cancer-related death in
the United States, 212,380 of new cases diagnosed and 160,390 deaths in 2007. Early detection of lung
cancers (less than 3 cm) can achieve a 90% ten-year survival rate. Early sign of the cancer is small lung
nodules. Current screening of the lung nodules is performed by high-resolution computed tomography (CT),
which carries a significant radiation and could increase the risk of getting cancer by as high as 2% according to
a recent report in The New England Journal of Medicine. In addition to the screening, more CT scans are
performed for follow-up and/or biopsy procedures. Reducing the radiation risk has been attempted by CT
manufacturers by both hardware optimization and software enhancement. We have been exploring adaptive
noise-treatment strategies to reconstruct similar image quality at significantly low mAs level for ultra low-dose
CT applications on currently available hardware configuration. Iterative image reconstruction under a
statistical cost function is one of the strategies which needs powerful computing engine (costs more than a half
million dollars). Analytical image reconstruction after data restoration by a statistical cost function is another
strategy which generates similar results as the iterative means with a dramatic reduction of computing burden.
Our pilot studies by both phantom and volunteer experiments have demonstrated great potential of the latter
restoration strategy for radiation reduction while retaining the image quality and reconstruction speed on
currently available CT scanners. The proposed specific aims to further explore the potential for screening lung
nodules are:
(SA-1). To further investigate the adaptive noise-treatment strategies toward as low mAs as achievable
for lung screening:
Because the first and second moments of low-mAs CT data contain the essential statistical information
about the noise (higher order moments have less impact on noise reduction), we will study the properties of
sample mean and variance of the data as mAs level goes down as low as achievable. In addition, data
correlations in the three-dimensional spatial domain associated with tomographic imaging will be investigated.
Both the noise properties and data correlation will be incorporated into a statistical cost function, i.e.,
Kharhunen-Lo¿ve domain penalized weighted least-squares, which can be efficiently minimized for data
restoration by an analytical fashion at the highest speed. Image reconstruction from the restored data will also
be analytical at the highest speed. For comparison purpose, iterative image reconstruction under a similar
statistical cost function will be refined.
(SA-2). To evaluate the investigated adaptive strategies by the detection of small lung nodules:
The presented strategies will be first evaluated by repeated experiments on anthropomorphic phantoms
with variable low mAs protocols using noise-resolution tradeoff measure and receiver operating characteristics
(ROC) and channelized Hotelling trace (CHT) observer studies. Then the evaluation will be on patient lung
nodule detection with comparison to currently-used mAs level by a same CT scanner, where quantitative
measures will be made using performance equivalence tests and ROC studies. The successfully evaluated
strategies may lead to a large clinical trial for ultra low-dose CT screening of the lung nodules, and could be
extended to screening of other vital organs, such as the colon, heart, and breasts.
PHS 398 (Rev. 04/06) Page __1___ Continuation Format Page
| Status | Finished |
|---|---|
| Effective start/end date | 07/1/10 → 04/30/17 |
Funding
- National Cancer Institute: $1,551,848.00
Fingerprint
Explore the research topics touched on by this project. These labels are generated based on the underlying awards/grants. Together they form a unique fingerprint.