Skip to main navigation Skip to search Skip to main content

A clinical evaluation of total variation-Stokes image reconstruction strategy for low-dose CT imaging of the chest

  • Stony Brook University

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

1 Scopus citations

Abstract

One hundred "normal-dose"? computed tomography (CT) studies of the chest (i.e., 1,160 projection views, 120kVp, 100mAs) data sets were acquired from the patients who were scheduled for lung biopsy at Stony Brook University Hospital under informed consent approved by our Institutional Review Board. To mimic low-dose CT imaging scenario (i.e., sparse-view scan), sparse projection views were evenly extracted from the total 1,160 projections of each patient and the total radiation dose was reduced according to how many sparse views were selected. A standard filtered backprojection (FBP) algorithm was applied to the 1160 projections to produce reference images for comparison purpose. In the low-dose scenario, both the FBP and total variation-stokes (TVS) algorithms were applied to reconstruct the corresponding low-dose images. The reconstructed images were evaluated by an experienced thoracic radiologist against the reference images. Both the low-dose reconstructions and the reference images were displayed on a 4- megapixel monitor in soft tissue and lung windows. The images were graded by a five-point scale from 0 to 4 (0, nondiagnostic; 1, severe artifact with low confidence; 2, moderate artifact or moderate diagnostic confidences; 3, mild artifact or high confidence; 4, well depicted without artifacts). Quantitative evaluation measurements such as standard deviations for different tissue types and universal quality index were also studied and reported for the results. The evaluation concluded that the TVS can reduce the view number from 1,160 to 580 with slightly lower scores as the reference, resulting in a dose reduction to close 50%.

Original languageEnglish
Title of host publicationMedical Imaging 2015
Subtitle of host publicationPhysics of Medical Imaging
EditorsChristoph Hoeschen, Despina Kontos, Christoph Hoeschen
PublisherSPIE
ISBN (Electronic)9781628415025
DOIs
StatePublished - 2015
EventMedical Imaging 2015: Physics of Medical Imaging - Orlando, United States
Duration: Feb 22 2015Feb 25 2015

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume9412
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2015: Physics of Medical Imaging
Country/TerritoryUnited States
CityOrlando
Period02/22/1502/25/15

Keywords

  • Image reconstruction
  • Sparse-view
  • Total variation stokes

Fingerprint

Dive into the research topics of 'A clinical evaluation of total variation-Stokes image reconstruction strategy for low-dose CT imaging of the chest'. Together they form a unique fingerprint.

Cite this