TY - GEN
T1 - A dual quaternion based method for estimating margins for planning target volumes in radiotherapy
AU - Ge, Q. J.
AU - Yu, Zihan
AU - Langer, Mark
N1 - Publisher Copyright:
Copyright © 2020 ASME
PY - 2020
Y1 - 2020
N2 - This objective of this paper is to develop a dual quaternion based method for estimating target volumes in radiation therapy for head and neck cancer. Inaccuracies in radiation targeting are responsible for incidental exposure of healthy adjacent tissues, causing significant morbidity and mortality. This paper focuses on inaccuracies incurred when a tumor is displaced during treatment. To address this problem, the clinical target must be expanded to cover the region through which the tumor might move. The resulting expanded target is known as the Planning Target Volume (PTV). In the current practice, the rotational components of displacements are neglected, producing planning target volumes that either miss the true target motion or are larger than needed to cover the target path. By using the dual quaternion based kinematic formulation, this paper represents and captures both translational and rotational inaccuracies. It then presents a framework for calculating the PTV swept out by the target as it shifts within its range of translations and rotations.
AB - This objective of this paper is to develop a dual quaternion based method for estimating target volumes in radiation therapy for head and neck cancer. Inaccuracies in radiation targeting are responsible for incidental exposure of healthy adjacent tissues, causing significant morbidity and mortality. This paper focuses on inaccuracies incurred when a tumor is displaced during treatment. To address this problem, the clinical target must be expanded to cover the region through which the tumor might move. The resulting expanded target is known as the Planning Target Volume (PTV). In the current practice, the rotational components of displacements are neglected, producing planning target volumes that either miss the true target motion or are larger than needed to cover the target path. By using the dual quaternion based kinematic formulation, this paper represents and captures both translational and rotational inaccuracies. It then presents a framework for calculating the PTV swept out by the target as it shifts within its range of translations and rotations.
UR - https://www.scopus.com/pages/publications/85096089302
U2 - 10.1115/DETC2020-22569
DO - 10.1115/DETC2020-22569
M3 - Conference contribution
AN - SCOPUS:85096089302
T3 - Proceedings of the ASME Design Engineering Technical Conference
BT - 44th Mechanisms and Robotics Conference (MR)
PB - American Society of Mechanical Engineers (ASME)
T2 - ASME 2020 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference, IDETC-CIE 2020
Y2 - 17 August 2020 through 19 August 2020
ER -