Skip to main navigation Skip to search Skip to main content

A novel approach for enhanced nanoparticle-sized bone substitute adhesion to chemically treated peri-implantitis-affected implant surfaces: An in vitro proof-of-principle study

  • Al-Azhar University
  • Ain Shams University

Research output: Contribution to journalArticlepeer-review

13 Scopus citations

Abstract

Background: The objective of this study is to evaluate micro and nano-hydroxyapatite (NHA) blended clot adhesion to citric acid-conditioned peri-implantitis-affected surfaces. Methods: Forty hopeless implants with peri-implantitis designated for removal were included in this study. Implants were divided into eight groups of five each: group 1 (G1) test areas were coated with hydroxyapatite of a microparticle size (MHA); group 2 (G2) test areas were coated with NHA; group 3 (G3) implants were coated with MHA after surface conditioning using citric acid; group 4 (G4) samples were treated in the same manner as in G3 except for the use of NHA; group 5 (G5) samples were coated without surface treatment with MHA mixed with whole human blood; group 6 (G6) implant samples were treated in the same manner as in G5 except for the use of NHA; group 7 (G7) implant samples were treated in the same way as in G5 plus surface conditioning using citric acid; and group 8 (G8) samples were treated in the same manner as in G7 except for the use of NHA. All implants in all groups were agitated for 3 minutes in phosphate- buffered saline. All samples were prepared for scanning electron microscopy evaluation. Results: G1 and G2 non-etched implants coated with MHA or NHA sizes were devoid of any bone particle adhesion to the peri-implantitis-affected surfaces. Contrary to the lack of microparticle adhesion to the root surface that was seen in G3, G4 acid-treated and NHA-coated samples revealed nearly complete coverage of the peri-implantitis-affected parts by the graft material. G5 non-etched, clot-blended MHA showed some areas of clot-blended graft adhesion covering 6.7% of the examined surfaces. G6 non-etched, clot-blended NHA showed NHA retention within the fibrin strands in areas where the implant surface pores were exposed (24.3%). G7 acid-treated and clot-blended MHA-treated implant surfaces showed partial coverage of the implant surface with detached fibrin clot-blended graft material (31.4%). G8 acid-treated and NHA clotblended graft-coated implants showed complete coverage of the implant surface by the clot-blended graft material (93.4%). Conclusion: Peri-implantitis-affected surface conditioning with citric acid improves NHA-blended clot adhesion to titanium implant surfaces.

Original languageEnglish
Pages (from-to)239-247
Number of pages9
JournalJournal of Periodontology
Volume84
Issue number2
DOIs
StatePublished - Feb 2013

Keywords

  • Bone regeneration
  • Citric-acid etching
  • Implant care
  • Nanotechnology
  • Osseointegration
  • Peri-implantitis

Fingerprint

Dive into the research topics of 'A novel approach for enhanced nanoparticle-sized bone substitute adhesion to chemically treated peri-implantitis-affected implant surfaces: An in vitro proof-of-principle study'. Together they form a unique fingerprint.

Cite this