Active tactile sensibility of brånemark protocol prostheses: A case–control clinical study

  • Nathalia Moraes
  • , Eduardo Moraes
  • , Tiago Anastacio
  • , Licínio Silva
  • , Aldir Machado
  • , José Schoichet
  • , Raphael Monte Alto
  • , Rafael Mello-Machado
  • , Angelo Cardarelli
  • , Carlos Fernando de Almeida Barros Mourão
  • , Priscila Casado
  • , Georgios Romanos
  • Universidade Federal Fluminense
  • De Moraes Institution
  • Universidade Iguaçu
  • Vita-Salute San Raffaele University

Research output: Contribution to journalArticlepeer-review

3 Scopus citations

Abstract

Few studies have assessed active tactile sensibility in patients rehabilitated with implants. Improved knowledge about functional tactile sensibility will contribute to several clinical applications, such as protocols for immediate loading, prosthesis design, occlusal improvement in implantology, and physiological integration of implant-supported prostheses. The present study evaluated active tactile sensibility in patients rehabilitated with Brånemark-type mandibular prostheses that impede the total mucosa-supported maxillary prosthesis. Thirty-five subjects participated in this study. The experimental group (n = 18) inclusion criteria were as follows: Brånemark-type prosthesis and a total mucosa-supported maxillary prosthesis. The control group (n = 17) was composed of participants with complete healthy dentition. Carbon foils with different thicknesses (12 µm, 24 µm, 40 µm, 80 µm, and 200 µm) were placed in the premolar region to evaluate the brink of active oral tactile sensibility. The researchers assessed the participants 120 times. After evaluation, we observed a statistical difference (p < 0.05) between the groups. Additionally, the degree of sensibility was found for all thicknesses, except for 12 µm, on both sides. There was a more significant increase in perception in the control group as the carbon thickness increased. The tactile sensibility threshold was 2.5 times greater for participants with prostheses. Thus, the tactile sensibility for mandibular implant-supported and maxillary mucosa-supported prostheses is significantly lower than that of dentate patients, which was detected above the thickness of 80 µm; in patients with natural dentition, different thicknesses were seen starting from 24 µm.

Original languageEnglish
Article number4644
JournalMaterials
Volume14
Issue number16
DOIs
StatePublished - Aug 2 2021

Keywords

  • Active tactile sensibility
  • Clinical research
  • Dental implant
  • Occlusion
  • Prosthodontics

Fingerprint

Dive into the research topics of 'Active tactile sensibility of brånemark protocol prostheses: A case–control clinical study'. Together they form a unique fingerprint.

Cite this