Skip to main navigation Skip to search Skip to main content

An image processing approach to compensate for the bladder wall motion and deformation in MR cystography

  • Stony Brook University
  • Sichuan University
  • University of North Carolina at Chapel Hill

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

2 Scopus citations

Abstract

Bladder cancer becomes the 5th leading cancer incidence. Management of bladder tumor is difficult because of its high recurrence rate (as high as 80%) after resection. It causes tremendous suffering and stress to the patient and the family. A non-invasive means of evaluating the entire bladder wall, especially the wall thickness as a biomarker, is clinically desired. MRI can provide such a means because of the intrinsic contrast between the urine and the wall by T1 and T2 relaxations. However, an acquisition without signal average (short-time scan) suffers from low signal-to-noise ratio (SNR), while with signal average (long-time scan) introduces motion artifacts because of the bladder wall deformation due to urine inflow, intestines' peristalsis and lung breathing, etc. To enhance the SNR while mitigating the motion artifacts, we proposed an image-processing approach of acquiring repeated short-time scans without signal average and registering the repeated scans prior to average. The effectiveness of the approach depends on the noise level in the short-time scans and the robustness of the registration method. This pre-requisition leads us to investigate adequate pulse sequences for fully 3D data acquisition and registration method. After investigating several potential pulse sequences, we found the THRIVE pulse sequence with TR=6.23ms, TE=3.87ms, sampling size of 208x100, and flip angle of 10 degrees produced adequate tradeoff of noise and contrast in images of 224x224 array with voxel size of 0.9375x0.9375x1.0 mm3. Then a group-wise B-spline based 3D deformable algorithm was developed to register the short-time scans for compensating the bladder wall motion. Results from volunteer and patient studies demonstrated the effectiveness of the presented simple, innovative approach in reducing bladder motion, enhancing the SNR and preserving edge details for imaging the bladder wall and, therefore, facilitating the measure of the wall thickness and detecting bladder wall abnormality.

Original languageEnglish
Title of host publication2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2011
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages3061-3065
Number of pages5
ISBN (Print)9781467301183
DOIs
StatePublished - 2011
Event2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2011 - Valencia, Spain
Duration: Oct 23 2011Oct 29 2011

Publication series

NameIEEE Nuclear Science Symposium Conference Record
ISSN (Print)1095-7863

Conference

Conference2011 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2011
Country/TerritorySpain
CityValencia
Period10/23/1110/29/11

Fingerprint

Dive into the research topics of 'An image processing approach to compensate for the bladder wall motion and deformation in MR cystography'. Together they form a unique fingerprint.

Cite this