Skip to main navigation Skip to search Skip to main content

Assessing Soft-Tissue Shrinkage Estimates in Museum Specimens Imaged With Diffusible Iodine-Based Contrast-Enhanced Computed Tomography (diceCT)

  • Brandon P. Hedrick
  • , Laurel Yohe
  • , Abby Vander Linden
  • , Liliana M. Dávalos
  • , Karen Sears
  • , Alexa Sadier
  • , Stephen J. Rossiter
  • , Kalina T.J. Davies
  • , Elizabeth Dumont
  • Harvard University
  • Stony Brook University
  • University of Massachusetts
  • University of Illinois at Urbana-Champaign
  • Queen Mary University of London
  • University of California Merced

Research output: Contribution to journalArticlepeer-review

52 Scopus citations

Abstract

The increased accessibility of soft-tissue data through diffusible iodine-based contrast-enhanced computed tomography (diceCT) enables comparative biologists to increase the taxonomic breadth of their studies with museum specimens. However, it is still unclear how soft-tissue measurements from preserved specimens reflect values from freshly collected specimens and whether diceCT preparation may affect these measurements. Here, we document and evaluate the accuracy of diceCT in museum specimens based on the soft-tissue reconstructions of brains and eyes of five bats. Based on proxies, both brains and eyes were roughly 60% of the estimated original sizes when first imaged. However, these structures did not further shrink significantly over a 4-week staining interval, and 1 week in 2.5% iodine-based solution yielded sufficient contrast for differentiating among soft-tissues. Compared to six fresh bat specimens imaged shortly after field collection (not fixed in ethanol), the museum specimens had significantly lower relative volumes of the eyes and brains. Variation in field preparation techniques and conditions, and long-term storage in ethanol may be the primary causes of shrinkage in museum specimens rather than diceCT staining methodology. Identifying reliable tissue-specific correction factors to adjust for the shrinkage now documented in museum specimens requires future work with larger samples.

Original languageEnglish
Pages (from-to)284-291
Number of pages8
JournalMicroscopy and Microanalysis
Volume24
Issue number3
DOIs
StatePublished - Jun 1 2018

Keywords

  • bats
  • diceCT
  • iodine-staining
  • microCT
  • shrinkage

Fingerprint

Dive into the research topics of 'Assessing Soft-Tissue Shrinkage Estimates in Museum Specimens Imaged With Diffusible Iodine-Based Contrast-Enhanced Computed Tomography (diceCT)'. Together they form a unique fingerprint.

Cite this