Cancer yield and patterns of follow-up for BI-RADS category 3 after screening mammography recall in the national mammography database

  • Wendie A. Berg
  • , Jeremy M. Berg
  • , Edward A. Sickles
  • , Elizabeth S. Burnside
  • , Margarita L. Zuley
  • , Robert D. Rosenberg
  • , Cindy S. Lee
  • University of Pittsburgh
  • University of California at San Francisco
  • University of Wisconsin-Madison
  • Radiology Associates of Albuquerque

Research output: Contribution to journal › Article › peer-review

43 Scopus citations

Abstract

Background: The literature supports the use of short-interval follow-up as an alternative to biopsy for lesions assessed as probably benign, Breast Imaging Reporting and Data System (BI-RADS) category 3, with an expected malignancy rate of less than 2%. Purpose: To assess outcomes from 6-, 12-, and 24-month follow-up of probably benign findings first identified at recall from screening mammography in the National Mammography Database (NMD). Materials and Methods: This retrospective study included women recalled from screening mammography with BI-RADS category 3 assessment at additional evaluation from January 2009 through March 2018 from 471 NMD facilities. Only the first BI-RADS category 3 occurrence for women aged 25 years or older with no personal history of breast cancer was analyzed, with biopsy or 2-year imaging follow-up. Cancer yield and positive predictive value of biopsies performed (PPV3) were determined at each follow-up. Results: Among 45 202 women (median age, 55 years; range, 25–90 years) with a BI-RADS category 3 lesion, 1574 (3.5%) underwent biopsy at the time of lesion detection, yielding 72 cancers (cancer yield, 4.6%; 72 of 1574 women). For the remaining 43 628 women who accepted surveillance, 922 were seen within 90 days (with 78 lesions biopsied and 12 [15%] classified as malignant). The women still in surveillance (31 465 of 43 381 women [72.5%]) underwent follow-up mammography at 6 months. Of 3001 (9.5%) lesions biopsied, 456 (15.2%) were malignant (cancer yield, 1.5%; 456 of 31 465 women; 95% confidence interval [CI]: 1.3%, 1.6%). Among 18 748 of 25 997 women (72.1%) in surveillance who underwent follow-up at 12 months, 1219 (6.5%) underwent biopsy with 230 (18.9%) malignant lesions found (cancer yield, 1.2%; 230 of 18 748 women; 95% CI: 1.1%, 1.4%). Through 2-year follow-up, the biopsy rate was 11.2% (4894 of 43 628 women) with a cancer yield of 1.86% (810 malignancies found among 43 628 women; 95% CI: 1.73%, 1.98%) and a PPV3 of 16.6% (810 malignancies found among 4894 women). Conclusion: In the National Mammography Database, Breast Imaging Reporting and Data System (BI-RADS) category 3 use is appropriate, with 1.86% cumulative cancer yield through 2-year follow-up. Of 810 malignancies, 468 (57.8%) were diagnosed at or before 6 months, validating necessity of short-interval follow-up of mammographic BI-RADS category 3 findings.

Original languageEnglish
Pages (from-to)32-41
Number of pages10
JournalRadiology
Volume296
Issue number1
DOIs
StatePublished - Jul 2020

Fingerprint

Dive into the research topics of 'Cancer yield and patterns of follow-up for BI-RADS category 3 after screening mammography recall in the national mammography database'. Together they form a unique fingerprint.

Cite this