TY - GEN
T1 - Comparison of experimental temperature results with numerical modeling predictions of a real-world compact data center facility
AU - Amemiya, Yasuo
AU - Hamann, Hendrik
AU - Schappert, Michael
AU - Van Kessel, Theodore
AU - Iyengar, Madhusudan
AU - O'Boyle, Martin
AU - Shen, Jing
PY - 2007
Y1 - 2007
N2 - In this paper we address the high level of validation of commercially available numerical predictive tools, namely CFD models, for data center applications. Experimental data at a real world facility is compared with computational results. Specifically, a recently developed temperature measurement tool is used to capture three dimensional temperature profiles of the facility with very fine spatial granularity. These detailed contours based on actual measurements reveal hot air recirculation patterns in the room as well as variable utilization levels of the room air-conditioning units. We compare these experimental temperature distributions measured using a novel 3D mapping tool with CFD thermal modeling results. An algorithm for generating CFD models for real world systems is proposed and demonstrated. It is found that due to the extensive inaccuracies in rapidly gathered input data as well as inherent limitations of the model, there can be significant discrepancies between predicted and actual temperatures. In addition to steady state measurements, transient data was also collected and are presented. Knowledge of the transient temperature profiles at different parts of the room allows an estimation of the temporal behavior of the data center. Transient temperature fluctuations are presented which capture the real variations in the system boundary conditions, for example the temperature of the chilled water to the air conditioning units, or the power dissipation of the servers over time.
AB - In this paper we address the high level of validation of commercially available numerical predictive tools, namely CFD models, for data center applications. Experimental data at a real world facility is compared with computational results. Specifically, a recently developed temperature measurement tool is used to capture three dimensional temperature profiles of the facility with very fine spatial granularity. These detailed contours based on actual measurements reveal hot air recirculation patterns in the room as well as variable utilization levels of the room air-conditioning units. We compare these experimental temperature distributions measured using a novel 3D mapping tool with CFD thermal modeling results. An algorithm for generating CFD models for real world systems is proposed and demonstrated. It is found that due to the extensive inaccuracies in rapidly gathered input data as well as inherent limitations of the model, there can be significant discrepancies between predicted and actual temperatures. In addition to steady state measurements, transient data was also collected and are presented. Knowledge of the transient temperature profiles at different parts of the room allows an estimation of the temporal behavior of the data center. Transient temperature fluctuations are presented which capture the real variations in the system boundary conditions, for example the temperature of the chilled water to the air conditioning units, or the power dissipation of the servers over time.
UR - https://www.scopus.com/pages/publications/40449127545
U2 - 10.1115/IPACK2007-33899
DO - 10.1115/IPACK2007-33899
M3 - Conference contribution
AN - SCOPUS:40449127545
SN - 0791842770
SN - 9780791842775
T3 - 2007 Proceedings of the ASME InterPack Conference, IPACK 2007
SP - 871
EP - 876
BT - 2007 Proceedings of the ASME InterPack Conference, IPACK 2007
T2 - ASME Electronic and Photonics Packaging Division
Y2 - 8 July 2007 through 12 July 2007
ER -