Skip to main navigation Skip to search Skip to main content

Cooling force measurements at CELSIUS

  • B. Gålnander
  • , A. V. Fedotov
  • , V. N. Litvinenko
  • , T. Lofnes
  • , A. O. Sidorin
  • , A. V. Smirnov
  • , V. Ziemann
  • Uppsala University
  • Brookhaven National Laboratory
  • Joint Institute for Nuclear Research

Research output: Contribution to journalConference articlepeer-review

3 Scopus citations

Abstract

The design of future high energy coolers relies heavily on extending the results of cooling force measurements into new regimes by using simulation codes. In order to carefully benchmark these codes we have accurately measured the longitudinal friction force in CELSIUS by recording the phase shift between the beam and the RF voltage while varying the RF frequency. Moreover, parameter dependencies on the electron current, solenoid magnetic field and magnetic field alignment were carried out.

Original languageEnglish
Pages (from-to)259-264
Number of pages6
JournalAIP Conference Proceedings
Volume821
DOIs
StatePublished - Mar 20 2006
EventBEAM COOLING AND RELATED TOPICS: International Workshop on Beam Cooling and Related Topics - COOL05 - Galena, IL, United States
Duration: Sep 18 2005Sep 23 2005

Keywords

  • Electron cooling
  • Friction force

Fingerprint

Dive into the research topics of 'Cooling force measurements at CELSIUS'. Together they form a unique fingerprint.

Cite this