Three prototypes of current leads (6500 A, 10 × 100 A and 4 × 100 A) for the HERA accelerator were designed, built and tested. The measured total cooling load of these current leads in the refrigerator mode of operation was 3.2, 3.9 and 2.4 W/kA, respectively. Subsequently, these current leads were produced in quantity by a commercial outfit and they are now in the process of assembly within the HERA cryogenic systems in DESY. The essential technical details and experimental results are described.