Diagnostic accuracy of digital mammography in patients with dense breasts who underwent problem-solving mammography: Effects of image processing and lesion type

  • Elodia B. Cole
  • , Etta D. Pisano
  • , Emily O. Kistner
  • , Keith E. Muller
  • , Marylee E. Brown
  • , Stephen A. Feig
  • , Roberta A. Jong
  • , Andrew D.A. Maidment
  • , Melinda J. Staiger
  • , Cherie M. Kuzmiak
  • , Rita I. Freimanis
  • , Nadine Lesko
  • , Eric L. Rosen
  • , Ruth Walsh
  • , Margaret Williford
  • , M. Patricia Braeuning
  • University of North Carolina at Chapel Hill
  • Icahn School of Medicine at Mount Sinai
  • University of Toronto
  • Thomas Jefferson University
  • Wake Forest University
  • Duke University
  • Health Alliance

Research output: Contribution to journalArticlepeer-review

69 Scopus citations

Abstract

PURPOSE: To determine effects of lesion type (calcification vs mass) and image processing on radiologist's performance for area under the receiver operating characteristic curve (AUC), sensitivity, and specificity for detection of masses and calcifications with digital mammography in women with mammographically dense breasts. MATERIALS AND METHODS: This study included 201 women who underwent digital mammography at seven U.S. and Canadian medical centers. Three imageprocessing algorithms were applied to the digital images, which were acquired with Fischer, General Electric, and Lorad digital mammography units. Eighteen readers participated in the reader study (six readers per algorithm). Baseline values for reader performance with screen-film mammograms were obtained through the additional interpretation of 179 screen-film mammograms. A repeated-measures analysis of covariance allowing unequal slopes was used in each of the nine analyses (AUC, sensitivity, and specificity for each of three machines). Bonferroni correction was used. RESULTS: Although lesion type did not affect the AUC or sensitivity for Fischer digital images, it did affect specificity (P = .0004). For the General Electric digital images, AUC, sensitivity, and specificity were not affected by lesion type. For Lorad digital images, the results strongly suggested that lesion type affected AUC and sensitivity (P < .0001). None of the three image-processing methods tested affected the AUC, sensitivity, or specificity for the Fischer, General Electric, or Lorad digital images. CONCLUSION: Findings in this study indicate that radiologist's interpretation accuracy in interpreting digital mammograms depends on lesion type. Interpretation accuracy was not influenced by the image-processing method.

Original languageEnglish
Pages (from-to)153-160
Number of pages8
JournalRadiology
Volume226
Issue number1
DOIs
StatePublished - Jan 1 2003

Keywords

  • Breast radiography, comparative studies
  • Diagnostic radiology, observer performance
  • Images, processing
  • Radiography, digital
  • Screens and films

Fingerprint

Dive into the research topics of 'Diagnostic accuracy of digital mammography in patients with dense breasts who underwent problem-solving mammography: Effects of image processing and lesion type'. Together they form a unique fingerprint.

Cite this