Abstract

The imaging performance of an indirect flat panel detector (I-FPD) is fundamentally limited by that of its scintillator. The scintillator's modulation transfer function (MTF) varies as a function of the depth of x-ray interaction in the layer, due to differences in the lateral spread of light before detection by the optical sensor. This variation degrades the spatial frequency-dependent detective quantum efficiency (DQE(f)) of I-FPDs, and is quantified by the Lubberts effect. The depth-dependent MTFs of various scintillators used in I-FPDs have been estimated using Monte Carlo simulations, but have never been measured directly. This work presents the first experimental measurements of the depth-dependent MTF of thallium-doped cesium iodide (CsI) and terbium-doped Gd2O2S (GOS) scintillators with thickness ranging from 200 - 1000 μm. Light bursts from individual x-ray interactions occurring at known, fixed depths within a scintillator are imaged using an ultra-high-sensitivity II-EMCCD (image-intensifier, electron multiplying charge coupled device) camera. X-ray interaction depth in the scintillator is localized using a micro-slit beam of parallel synchrotron radiation (32 keV), and varied by translation in 50 ± 1 μm depth intervals. Fourier analysis of the imaged light bursts is used to deduce the MTF versus x-ray interaction depth z. Measurements of MTF(z,f) are used to calculate presampling MTF(f) with RQA-M3, RQA5 and RQA9 beam qualities and compared with conventional slanted edge measurements. Images of the depth-varying light bursts are used to derive each scintillator's Lubberts function for a 32 keV beam.

Original languageEnglish
Title of host publicationMedical Imaging 2017
Subtitle of host publicationPhysics of Medical Imaging
EditorsTaly Gilat Schmidt, Joseph Y. Lo, Thomas G. Flohr
PublisherSPIE
ISBN (Electronic)9781510607095
DOIs
StatePublished - 2017
EventMedical Imaging 2017: Physics of Medical Imaging - Orlando, United States
Duration: Feb 13 2017Feb 16 2017

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume10132
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2017: Physics of Medical Imaging
Country/TerritoryUnited States
CityOrlando
Period02/13/1702/16/17

Keywords

  • Cesium iodide
  • Digital radiography
  • Flat panel detector
  • Lubberts
  • Modulation transfer function
  • Scintillator
  • Spatial resolution
  • Synchrotron

Fingerprint

Dive into the research topics of 'Direct measurement of Lubberts effect in CsI:Tl scintillators using single x-ray photon imaging'. Together they form a unique fingerprint.

Cite this