T1 - Energy efficiency and air quality considerations in airside economized data centers
AU - Klein, Levente J.
AU - Bermudez, Sergio A.
AU - Marianno, Fernando J.
AU - Hamann, Hendrik F.
AU - Singh, Prabjit
N1 - Publisher Copyright:
Copyright © 2015 by ASME.
PY - 2015
Y1 - 2015
N2 - Many data center operators are considering the option to convert from mechanical to free air cooling to improve energy efficiency. The main advantage of free air cooling is the elimination of chiller and Air Conditioning Unit operation when outdoor temperature falls below the data center temperature set point. Accidental introduction of gaseous pollutants in the data center along the fresh air and potential latency in response of control infrastructure to extreme events are some of the main concerns for adopting outside air cooling in data centers. Recent developments of ultra-high sensitivity corrosion sensors enable the real time monitoring of air quality and thus allow a better understanding of how airflow, relative humidity, and temperature fluctuations affect corrosion rates. Both the sensitivity of sensors and wireless networks ability to detect and react rapidly to any contamination event make them reliable tools to prevent corrosion related failures. A feasibility study is presented for eight legacy data centers that are evaluated to implement free air cooling.
AB - Many data center operators are considering the option to convert from mechanical to free air cooling to improve energy efficiency. The main advantage of free air cooling is the elimination of chiller and Air Conditioning Unit operation when outdoor temperature falls below the data center temperature set point. Accidental introduction of gaseous pollutants in the data center along the fresh air and potential latency in response of control infrastructure to extreme events are some of the main concerns for adopting outside air cooling in data centers. Recent developments of ultra-high sensitivity corrosion sensors enable the real time monitoring of air quality and thus allow a better understanding of how airflow, relative humidity, and temperature fluctuations affect corrosion rates. Both the sensitivity of sensors and wireless networks ability to detect and react rapidly to any contamination event make them reliable tools to prevent corrosion related failures. A feasibility study is presented for eight legacy data centers that are evaluated to implement free air cooling.
UR - https://www.scopus.com/pages/publications/84954049402
U2 - 10.1115/IPACK2015-48349
DO - 10.1115/IPACK2015-48349
M3 - Conference contribution
AN - SCOPUS:84954049402
T3 - ASME 2015 International Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Microsystems, InterPACK 2015, collocated with the ASME 2015 13th International Conference on Nanochannels, Microchannels, and Minichannels
BT - Thermal Management
PB - American Society of Mechanical Engineers
T2 - ASME 2015 International Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Microsystems, InterPACK 2015, collocated with the ASME 2015 13th International Conference on Nanochannels, Microchannels, and Minichannels
Y2 - 6 July 2015 through 9 July 2015
ER -