Abstract
To investigate airway physiology by use of inhaled aerosols, it is frequently necessary to measure the actual amount of material deposited on the airway wall as well as the site of particle deposition. To satisfy these needs, radiolabeled aerosols and gamma camera techniques have been used to measure regional deposition of inhaled particles. To make quantitative measurements of the amount deposited, previous investigators have used a "phantom" technique to indirectly calibrate the gamma camera for the attenuation of gamma rays through the lungs and chest wall. For this calibration, the phantom is a simulated lung containing a known amount of radioactivity. Radioactive counts emitted from the phantom are assumed to be attenuated in the same manner as the intact human lung. The present article describes a technique to determine directly the amount of inhaled aerosol deposited in the lung and simultaneously to calibrate the gamma camera for each individual subject. We used right angle light scattering and a gamma camera to measure individual values of the deposition fraction (DF) of inhaled aerosol deposited in the lung and the coefficient of attenuation (AC) of gamma rays in normal and obstructed lungs of human subjects. Radiolabeled monodisperse aerosols 1 and 2 μm in diameter were used. Knowledge of the activity of the inhaled aerosol (microcurie per liter), the volume inhaled, and the measured DF determined each subject's AC (counts per minute per microcurie). DF varied by an order of magnitude in normal (0.04 to 0.48) and obstructed (0.16 to 0.75) of subjects. AC also varied significantly in normal subjects (124 to 790) and patients (112 to 373). Factors important in the observed variation in values of AC included body surface area and regional deposition pattern. Our results suggest that because of individual variation in thoracic geometry and deposition pattern, the use of single value phantom calculations may not accurately reflect the amount of aerosol deposited in the lung. We suggest that attempts to correlate changes in pulmonary function with quantitative inhalation challenge require direct determination of the dose entering the lung for each individual patient.
| Original language | English |
|---|---|
| Pages (from-to) | 252-257 |
| Number of pages | 6 |
| Journal | The Journal of Allergy and Clinical Immunology |
| Volume | 75 |
| Issue number | 2 |
| DOIs | |
| State | Published - Feb 1985 |
Fingerprint
Dive into the research topics of 'Evaluation of quantitative aerosol techniques for use in bronchoprovocation studies'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver