Evaluation of shear-induced platelet activation models under constant and dynamic shear stress loading conditions relevant to devices

  • Jawaad Sheriff
  • , João Silva Soares
  • , Michalis Xenos
  • , Jolyon Jesty
  • , Danny Bluestein
  • Stony Brook University
  • University of Ioannina

Research output: Contribution to journalArticlepeer-review

112 Scopus citations

Abstract

The advent of implantable blood-recirculating devices such as left ventricular assist devices and prosthetic heart valves provides a viable therapy for patients with end-stage heart failure and valvular disease. However, device-generated pathological flow patterns result in thromboembolic complications that require complex and lifelong anticoagulant therapy, which entails hemorrhagic risks and is not appropriate for certain patients. Optimizing the thrombogenic performance of such devices utilizing numerical simulations requires the development of predictive platelet activation models that account for variations in shear-loading rates characterizing blood flow through such devices. Platelets were exposed in vitro to both dynamic and constant shear stress conditions emulating those found in blood-recirculating devices in order to determine their shear-induced activation and sensitization response. Both these behaviors were found to be dependent on the shear loading rates, in addition to shear stress magnitude and exposure time. We then critically examined several current models and evaluated their predictive capabilities using these results. Shear loading rate terms were then included to account for dynamic aspects that are either ignored or partially considered by these models, and model parameters were optimized. Independent optimization for each of the two types of shear stress exposure conditions tested resulted in different sets of best-fit constants, indicating that universal optimization may not be possible. Inherent limitations of the current models require a paradigm shift from these integral-based discretized power law models to better address the dynamic conditions encountered in blood-recirculating devices.

Original languageEnglish
Pages (from-to)1279-1296
Number of pages18
JournalAnnals of Biomedical Engineering
Volume41
Issue number6
DOIs
StatePublished - Jun 2013

Keywords

  • Blood damage models
  • Blood flow
  • Cardiovascular devices
  • Damage accumulation
  • Platelet activation
  • Platelet sensitization