Abstract
Operational experience of the emittance compensated photoinjector at the Brookhaven Accelerator Test Facility (ATF) is presented in this paper. The photoinjector has demonstrated the stability and reliability required for UV and X-ray FEL applications. The RF gun has been routinely running at more than 100 MV/m peak acceleration field; the laser system of the photoinjector has achieved 2% peak to peak energy stability, 0.5% point stability and better than 2 ps timing jitter. The highest measured quantum efficiency of the Cu cathode is 0.05%. The electron beam bunch length was measured to be 10 ps using a linac RF phase scan. The normalized rms emittance for 0.5 nC charge was measured, to be from 1 to 2 mm rad, which agrees with PARMELA simulations.
| Original language | English |
|---|---|
| Pages (from-to) | 82-86 |
| Number of pages | 5 |
| Journal | Nuclear Inst. and Methods in Physics Research, A |
| Volume | 375 |
| Issue number | 1-3 |
| DOIs | |
| State | Published - Jun 11 1996 |