TY - GEN
T1 - Experimental characterizations of 4-D transverse phase-space of a compressed beam
AU - Zhou, F.
AU - Agusstson, R.
AU - Andonian, G.
AU - Cline, D.
AU - Murokh, A.
AU - Rosenzweig, J.
AU - Ben-Zvi, I.
AU - Yakimenko, V.
PY - 2005
Y1 - 2005
N2 - Coherent synchrotron radiation (CSR) may severely deteriorate electron beam qualities, such as distortion of energy spectrum and transverse phase-space in the bending plane when the beam transports through a magnetic bunch compressor. Recently some laboratories conducted some investigations on CSR effects but mostly focused on the measurements of emittance growth and energy spread and or/ energy loss. However, these parameters may not completely represent a fully compressed beam because its phase spaces may be severely distorted and thus some information may be lost if only these basic parameters are used. It is preferred to reconstruct six-dimensional phase spaces of a compressed beam using tomographic techniques in order to fully understand a beam affected by CSR effects. This report will focus on the four-dimensional transverse phase-space tomographic measurements for a fully compressed beam at 60-MeV energy. Its experimental characterizations at different beam parameters are preliminarily examined.
AB - Coherent synchrotron radiation (CSR) may severely deteriorate electron beam qualities, such as distortion of energy spectrum and transverse phase-space in the bending plane when the beam transports through a magnetic bunch compressor. Recently some laboratories conducted some investigations on CSR effects but mostly focused on the measurements of emittance growth and energy spread and or/ energy loss. However, these parameters may not completely represent a fully compressed beam because its phase spaces may be severely distorted and thus some information may be lost if only these basic parameters are used. It is preferred to reconstruct six-dimensional phase spaces of a compressed beam using tomographic techniques in order to fully understand a beam affected by CSR effects. This report will focus on the four-dimensional transverse phase-space tomographic measurements for a fully compressed beam at 60-MeV energy. Its experimental characterizations at different beam parameters are preliminarily examined.
UR - https://www.scopus.com/pages/publications/33847165369
U2 - 10.1109/PAC.2005.1591077
DO - 10.1109/PAC.2005.1591077
M3 - Conference contribution
AN - SCOPUS:33847165369
SN - 0780388593
SN - 9780780388598
T3 - Proceedings of the IEEE Particle Accelerator Conference
SP - 2263
EP - 2265
BT - Proceedings of the Particle Accelerator Conference, PAC 2005
T2 - Particle Accelerator Conference, PAC 2005
Y2 - 16 May 2005 through 20 May 2005
ER -