Skip to main navigation Skip to search Skip to main content

False positive reduction for wall thickness-based detection of colonic flat polyps via CT colonography

  • Marc Pomeroy
  • , Lihong C. Li
  • , Hao Han
  • , Xinzhou Wei
  • , Perry J. Pickhardt
  • , Zhengrong Liang
  • Stony Brook University
  • City University of New York
  • University of Wisconsin-Madison

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

1 Scopus citations

Abstract

Computer-aided detection (CAD) of flat polyps, in contrast to other polyp types, is challenging due to their lack of projections from the colonic surface and limited geometrical features that can be extracted from such polyps. In this paper, we present a new approach for CAD of flat polyps via colon wall thickness mapping, texture feature extraction and analysis. First, we integrated our previous work of detecting flat polyp candidates via colon wall thickness mapping into this study for automated detection of initial polyp candidates (IPCs). The colon wall segmentation is established on a coupled level-set method after the lumen is electronically cleansed by a sophisticated statistical algorithm, which considers the partial volume effect to preserve the mucosa layer details. The IPC detection was performed based on the wall thickness local pattern. From each IPC volume, we extracted the 14 Haralick texture features and 16 additional features that were previously demonstrated to improve polyp classification performance. Then, we adopted the Rpackage "randomForest" to classify the features for false positive (FP) reduction. We evaluated our method via 16 patient datasets. The proposed scheme achieved a high capacity in terms of the well-known area under the curve value of 0.930. The FPs was reduced to less than 3 FPs/per polyp. The experiment results demonstrate the feasibility of our method in achieving computer aided detection of flat polyps, therefore, improving the screening capability of computed tomography cololongraphy.

Original languageEnglish
Title of host publicationMedical Imaging 2017
Subtitle of host publicationComputer-Aided Diagnosis
EditorsNicholas A. Petrick, Samuel G. Armato
PublisherSPIE
ISBN (Electronic)9781510607132
DOIs
StatePublished - 2017
EventMedical Imaging 2017: Computer-Aided Diagnosis - Orlando, United States
Duration: Feb 13 2017Feb 16 2017

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume10134
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2017: Computer-Aided Diagnosis
Country/TerritoryUnited States
CityOrlando
Period02/13/1702/16/17

Keywords

  • Computer aided detection
  • CT colonography
  • Flat polyp
  • Texture features
  • Wall thickness

Fingerprint

Dive into the research topics of 'False positive reduction for wall thickness-based detection of colonic flat polyps via CT colonography'. Together they form a unique fingerprint.

Cite this