Abstract

This paper presents the detection and protection methods uniquely associated with three-level NPC voltage source converters. The line-to-ground fault can cause significant dc-link neutral voltage and therefore can be effectively detected and located through monitoring the voltage without extra hardware. The inner device short in the three-level phase-leg can lead to dclink voltage unbalance and doubling the stress on capacitors and devices, which must be suppressed for the safe operation of the converter. Two overvoltage limiting methods are proposed to limit the overvoltage. The design of both the ground fault detection and overvoltage limiting has been covered in the paper. The schemes are verified through simulation and experiments.

Original languageEnglish
Title of host publication2008 IEEE Industry Applications Society Annual Meeting, IAS'08
DOIs
StatePublished - 2008
Event2008 IEEE Industry Applications Society Annual Meeting, IAS'08 - Edmonton, AB, Canada
Duration: Oct 5 2008Oct 9 2008

Publication series

NameConference Record - IAS Annual Meeting (IEEE Industry Applications Society)
ISSN (Print)0197-2618

Conference

Conference2008 IEEE Industry Applications Society Annual Meeting, IAS'08
Country/TerritoryCanada
CityEdmonton, AB
Period10/5/0810/9/08

Keywords

  • Failure modes
  • Fault detection
  • Protection
  • Three-level neutral-point-clapmed converter

Fingerprint

Dive into the research topics of 'Fault detection and protection of three-level neutral-point-clamped PWM voltage source converters'. Together they form a unique fingerprint.

Cite this