Skip to main navigation Skip to search Skip to main content

Feasibility studies for extracting an input function for quantitative positron emission tomography using a wrist scanner

  • A. Kriplani
  • , D. J. Schlyer
  • , P. Vaska
  • , S. Southekal
  • , S. J. Park
  • , C. L. Woody
  • , S. P. Stoll
  • , S. Junnarkar
  • , J. F. Pratte
  • Stony Brook University
  • Brookhaven National Laboratory

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

2 Scopus citations

Abstract

Tracer kinetic modeling techniques for quantitative Positron emission tomography (PET) require an accurately measured radiotracer concentration in arterial blood as a function of time as an input to the model (arterial input function). Since the input function (IF) is derived from blood samples from the wrist arteries, a scanner is begin devised to detect radioactivity in the wrist as a function of time and extract an IF. A prototype using two detector pairs has been evaluated. The spatial resolution, sensitivity and the masking of the arterial signal by the surrounding wrist tissue radioactivity are determined. The results show that the detector was able to discriminate the arterial and venous flows from each other using planar coincidence images. MicroPET images of the wrist show that the radioactivity from the tissue does not interfere with the arterial signal. Minimization of venous and tissue interference, optimal number and placement of the detectors are being evaluated. The two detector pair prototype was used in a routine PET study.

Original languageEnglish
Title of host publication33rd Annual Northeast Bioengineering Conference - Engineering Innovations in Life Sciences and Healthcare, NEBC
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages51-53
Number of pages3
ISBN (Print)1424410339, 9781424410330
DOIs
StatePublished - 2007
Event33rd Annual Northeast Bioengineering Conference, NEBC - Stony Brook, NY, United States
Duration: Mar 10 2007Mar 11 2007

Publication series

NameProceedings of the IEEE Annual Northeast Bioengineering Conference, NEBEC
ISSN (Print)1071-121X

Conference

Conference33rd Annual Northeast Bioengineering Conference, NEBC
Country/TerritoryUnited States
CityStony Brook, NY
Period03/10/0703/11/07

Fingerprint

Dive into the research topics of 'Feasibility studies for extracting an input function for quantitative positron emission tomography using a wrist scanner'. Together they form a unique fingerprint.

Cite this