Skip to main navigation Skip to search Skip to main content

Front-end ASIC for spectroscopic readout of virtual Frisch-grid CZT bar sensors

  • Emerson Vernon
  • , Gianluigi De Geronimo
  • , Aleksey Bolotnikov
  • , Milutin Stanacevic
  • , Jack Fried
  • , Luis Ocampo Giraldo
  • , Graham Smith
  • , Kevin Wolniewicz
  • , Kim Ackley
  • , Cynthia Salwen
  • , John Triolo
  • , Don Pinelli
  • , Kenny Luong
  • Brookhaven National Laboratory
  • Stony Brook University
  • Idaho National Laboratory

Research output: Contribution to journalArticlepeer-review

16 Scopus citations

Abstract

Compact multi-channel radiation detectors rely on low noise front-end application specific integrated circuits (ASICs)to achieve high spectral resolution. Here, a new ASIC developed to readout virtual Frisch-grid cadmium zinc telluride (VFG CZT)detectors for gamma ray spectroscopy is presented. Corresponding to each ionizing event in the detector, the ASIC measures the amplitude and timing at the anode, the cathode and four pad sense electrodes associated with each sensor in a detector array. The ASIC is comprised of 52 channels of which there are 4 cathode channels and 48 channels which can be configured as either anode channels with a baseline of 250 mV or pad sense channels to process induced signals with a baseline of 1.2 V. With a static power dissipation of 3 mW, each channel performs low-noise charge amplification, high-order shaping, peak and timing detection along with analog storage and multiplexing. The overall channel linearity was better than ±1% with timing resolution down to 700 ps for charges greater than 8 fC in the 3 MeV range. With a 4 × 4 array of 6 mm × 6 mm × 20 mm virtual Frisch-grid bar sensors connected and biased, an electronic resolution of ≈ 270 erms for charges up to 100 fC in the 3.2 MeV range was measured. Spectral measurements obtained with the 3D correction technique demonstrated resolutions of 1.8% FWHM at 238 keV and 0.9% FWHM at 662 keV.

Original languageEnglish
Pages (from-to)1-11
Number of pages11
JournalNuclear Inst. and Methods in Physics Research, A
Volume940
DOIs
StatePublished - Oct 1 2019

Keywords

  • 3D
  • Application Specific Integrated Circuit (ASIC)
  • Cadmium Zinc telluride (CdZnTe or CZT)
  • Gamma ray
  • Low noise front-end
  • Mercuric iodide (HgI)
  • Mixed signal
  • Radiation detection
  • Spectroscopy
  • Thallium bromide (TlBr)
  • Virtual Frisch-grid

Fingerprint

Dive into the research topics of 'Front-end ASIC for spectroscopic readout of virtual Frisch-grid CZT bar sensors'. Together they form a unique fingerprint.

Cite this