TY - GEN
T1 - Fully 4D cardiac gated SPECT reconstruction with simultaneous compensation in KL domain
AU - Fan, Yi
AU - Jiao, Chun
AU - Lu, Hongbing
AU - Wang, Su
AU - Liang, Zhengrong
PY - 2008
Y1 - 2008
N2 - Recent researches have shown promise in applying KL transform to 4D gated sinogram for pre-reconstruction temporal smoothing and quasi-4D inversion of attenuated Radon transform. To achieve quantitative 4D reconstruction, this work aims to compensate for the major degradation factors, including distance-dependent collimator resolution variation and objectspecific photon scatter, simultaneously within the KL framework. To alleviate the influence of cardiac motion on reconstruction, heart motion was classified into several groups based on inter-frame similarities and each group underwent a corresponding KL transform. In the KL domain, non-stationary Poisson noise was stabilized by Anscombe transform and treated by adaptive Wiener filtration. Scatter contribution to the primary energy window was then estimated and removed based on photon detection energy spectrum and the triple-energywindow acquisition formula after noise treatment. The scattercorrected data was further subject to a depth-dependent deconvo ution, based on the distance frequency relationship, with measured detector response kernel in the KL domain. The deconvoluted sinograms were reconstructed by inverting the attenuated Radon transform for each KL component and the 4D SPECT images were obtained by a corresponding inverse KL transform for each group. The simultaneous compensation strategy in the KL domain was tested by computer simulations from digital phantoms of 128 cubic array and clinical data from a patient. The adaptive KL transform for different groups consisting of frames with similar activity dynamics showed noticeable improvement over our previous work of using a single KL transform for all frames. Improvement was also seen by theadaptive noise treatment of all the KL components over previous work of discarding the higher-order components. Further improvement by considering the scatter and resolution variation was demonstrated.
AB - Recent researches have shown promise in applying KL transform to 4D gated sinogram for pre-reconstruction temporal smoothing and quasi-4D inversion of attenuated Radon transform. To achieve quantitative 4D reconstruction, this work aims to compensate for the major degradation factors, including distance-dependent collimator resolution variation and objectspecific photon scatter, simultaneously within the KL framework. To alleviate the influence of cardiac motion on reconstruction, heart motion was classified into several groups based on inter-frame similarities and each group underwent a corresponding KL transform. In the KL domain, non-stationary Poisson noise was stabilized by Anscombe transform and treated by adaptive Wiener filtration. Scatter contribution to the primary energy window was then estimated and removed based on photon detection energy spectrum and the triple-energywindow acquisition formula after noise treatment. The scattercorrected data was further subject to a depth-dependent deconvo ution, based on the distance frequency relationship, with measured detector response kernel in the KL domain. The deconvoluted sinograms were reconstructed by inverting the attenuated Radon transform for each KL component and the 4D SPECT images were obtained by a corresponding inverse KL transform for each group. The simultaneous compensation strategy in the KL domain was tested by computer simulations from digital phantoms of 128 cubic array and clinical data from a patient. The adaptive KL transform for different groups consisting of frames with similar activity dynamics showed noticeable improvement over our previous work of using a single KL transform for all frames. Improvement was also seen by theadaptive noise treatment of all the KL components over previous work of discarding the higher-order components. Further improvement by considering the scatter and resolution variation was demonstrated.
UR - https://www.scopus.com/pages/publications/67649148400
U2 - 10.1109/NSSMIC.2008.4774216
DO - 10.1109/NSSMIC.2008.4774216
M3 - Conference contribution
AN - SCOPUS:67649148400
SN - 9781424427154
T3 - IEEE Nuclear Science Symposium Conference Record
SP - 4232
EP - 4237
BT - 2008 IEEE Nuclear Science Symposium Conference Record, NSS/MIC 2008
T2 - 2008 IEEE Nuclear Science Symposium Conference Record, NSS/MIC 2008
Y2 - 19 October 2008 through 25 October 2008
ER -