Skip to main navigation Skip to search Skip to main content

Genetically encoded calcium indicator with NTnC-like design and enhanced fluorescence contrast and kinetics

  • D. A. Doronin
  • , N. V. Barykina
  • , O. M. Subach
  • , V. P. Sotskov
  • , V. V. Plusnin
  • , O. A. Ivleva
  • , E. A. Isaakova
  • , A. M. Varizhuk
  • , G. E. Pozmogova
  • , A. Y. Malyshev
  • , I. V. Smirnov
  • , K. D. Piatkevich
  • , K. V. Anokhin
  • , G. N. Enikolopov
  • , F. V. Subach
  • Moscow Institute of Physics and Technology
  • Russian Academy of Sciences
  • Russian Research Centre Kurchatov Institute
  • Lomonosov Moscow State University
  • Federal Medical-Biological Agency
  • Academy of Sciences of the U.S.S.R.
  • Institute of Higher Nervous Activity and Neurophysiology of RAS
  • Massachusetts Institute of Technology

Research output: Contribution to journalArticlepeer-review

19 Scopus citations

Abstract

Background: The recently developed genetically encoded calcium indicator (GECI), called NTnC, has a novel design with reduced size due to utilization of the troponin C (TnC) as a Ca 2+ -binding moiety inserted into the mNeonGreen fluorescent protein. NTnC binds two times less Ca 2+ ions while maintaining a higher fluorescence brightness at the basal level of Ca 2+ in neurons as compared with the calmodulin-based GECIs, such as GCaMPs. In spite of NTnC's high brightness, pH-stability, and high sensitivity to single action potentials, it has a limited fluorescence contrast (F -Ca2+ /F +Ca2+ ) and slow Ca 2+ dissociation kinetics. Results: Herein, we developed a new NTnC-like GECI with enhanced fluorescence contrast and kinetics by replacing the mNeonGreen fluorescent subunit of the NTnC indicator with EYFP. Similar to NTnC, the developed indicator, named iYTnC2, has an inverted fluorescence response to Ca 2+ (i.e. becoming dimmer with an increase of Ca 2+ concentration). In the presence of Mg 2+ ions, iYTnC2 demonstrated a 2.8-fold improved fluorescence contrast in vitro as compared with NTnC. The iYTnC2 indicator has lower brightness and pH-stability, but similar photostability as compared with NTnC in vitro. Stopped-flow fluorimetry studies revealed that iYTnC2 has 5-fold faster Ca 2+ dissociation kinetics than NTnC. When compared with GCaMP6f GECI, iYTnC2 has up to 5.6-fold faster Ca 2+ association kinetics and 1.7-fold slower dissociation kinetics. During calcium transients in cultured mammalian cells, iYTnC2 demonstrated a 2.7-fold higher fluorescence contrast as compared with that for the NTnC. iYTnC2 demonstrated a 4-fold larger response to Ca 2+ transients in neuronal cultures than responses of NTnC. iYTnC2 response in neurons was additionally characterized using whole-cell patch clamp. Finally, we demonstrated that iYTnC2 can visualize neuronal activity in vivo in the hippocampus of freely moving mice using a nVista miniscope. Conclusions: We demonstrate that expanding the family of NTnC-like calcium indicators is a promising strategy for the development of the next generation of GECIs with smaller molecule size and lower Ca 2+ ions buffering capacity as compared with commonly used GECIs.

Original languageEnglish
Article number10
JournalBMC Biotechnology
Volume18
Issue number1
DOIs
StatePublished - Feb 13 2018

Keywords

  • Calcium imaging
  • Genetically encoded calcium indicator
  • Protein engineering

Fingerprint

Dive into the research topics of 'Genetically encoded calcium indicator with NTnC-like design and enhanced fluorescence contrast and kinetics'. Together they form a unique fingerprint.

Cite this