Skip to main navigation Skip to search Skip to main content

Improved area-simulating-volume method for 3D X-ray CT re-projection and back-projection operations

  • Stony Brook University
  • Air Force Medical University

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

1 Scopus citations

Abstract

Many studies have reported that the volume-weighting technique has advantages over the ray-tracing method in re-projection modality and the linear interpolation in back-projection operation for three-dimensional (3D) X-ray computed tomography (CT) imaging. However, the calculation of the intersecting volumes requires a high arithmetic complexity and can be difficult to implement practically. In this work, inspired by the previous work in area-simulating- volume (ASV) projector for 3D positron emission tomography, we developed an improved ASV (IASV) technique, which can fast and accurately calculate the intersection volume between the pencil-ray and the object for 3D cone-beam CT. In our re-projection study, a 3D Shepp-Logan digital phantom was performed to simulate projection data by the IASV and ray-tracing techniques, respectively. An analytical solution of the projection data was calculated based on the known densities and intersection length of the ray with the 3D phantom and used as a ground truth. The results demonstrated that the simulated projection data by IASV technique is smoother than the results from ray-tracing technique and closer to the analytical solution or ground truth. In addition to the comparison in re-projection, a series of digital and physical phantoms were performed to compare the IASV technique with conventional linear-interpolation technique for back-projection operation. Digital phantom study demonstrated that a uniformly distributed noise image was achieved by the proposed volume-weighting technique in stationary noise case. This observation was also verified in a study using repeated scans on a physical phantom.

Original languageEnglish
Title of host publication2013 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2013
PublisherInstitute of Electrical and Electronics Engineers Inc.
ISBN (Print)9781479905348
DOIs
StatePublished - 2013
Event2013 60th IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2013 - Seoul, Korea, Republic of
Duration: Oct 27 2013Nov 2 2013

Publication series

NameIEEE Nuclear Science Symposium Conference Record
ISSN (Print)1095-7863

Conference

Conference2013 60th IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2013
Country/TerritoryKorea, Republic of
CitySeoul
Period10/27/1311/2/13

Fingerprint

Dive into the research topics of 'Improved area-simulating-volume method for 3D X-ray CT re-projection and back-projection operations'. Together they form a unique fingerprint.

Cite this