Skip to main navigation Skip to search Skip to main content

Improved Identification of Venous Thromboembolism from Electronic Medical Records Using a Novel Information Extraction Software Platform

  • Raymund B. Dantes
  • , Shuai Zheng
  • , James J. Lu
  • , Michele G. Beckman
  • , Asha Krishnaswamy
  • , Lisa C. Richardson
  • , Sheri Chernetsky-Tejedor
  • , Fusheng Wang
  • Emory University
  • Centers for Disease Control and Prevention

Research output: Contribution to journalArticlepeer-review

16 Scopus citations

Abstract

Introduction: The United States federally mandated reporting of venous thromboembolism (VTE), defined by Agency for Healthcare Research & Quality Patient Safety Indicator 12 (AHRQ PSI-12), is based on administrative data, the accuracy of which has not been consistently demonstrated. We used IDEAL-X, a novel information extraction software system, to identify VTE from electronic medical records and evaluated its accuracy. Methods: Medical records for 13,248 patients admitted to an orthopedic specialty hospital from 2009 to 2014 were reviewed. Patient encounters were defined as a hospital admission where both surgery (of the spine, hip, or knee) and a radiology diagnostic study that could detect VTE was performed. Radiology reports were both manually reviewed by a physician and analyzed by IDEAL-X. Results: Among 2083 radiology reports, IDEAL-X correctly identified 176/181 VTE events, achieving a sensitivity of 97.2% [95% confidence interval (CI), 93.7%-99.1%] and specificity of 99.3% (95% CI, 98.9%-99.7%) when compared with manual review. Among 422 surgical encounters with diagnostic radiographic studies for VTE, IDEAL-X correctly identified 41 of 42 VTE events, achieving a sensitivity of 97.6% (95% CI, 87.4%-99.6%) and specificity of 99.8% (95% CI, 98.7%-100.0%). The performance surpassed that of AHRQ PSI-12, which had a sensitivity of 92.9% (95% CI, 80.5%-98.4%) and specificity of 92.9% (95% CI, 89.8%-95.3%), though only the difference in specificity was statistically significant (P<0.01). Conclusion: IDEAL-X, a novel information extraction software system, identified VTE from radiology reports with high accuracy, with specificity surpassing AHRQ PSI-12. IDEAL-X could potentially improve detection and surveillance of many medical conditions from free text of electronic medical records.

Original languageEnglish
Pages (from-to)e54-e60
JournalMedical Care
Volume56
Issue number9
DOIs
StatePublished - Sep 1 2018

Keywords

  • machine learning
  • natural language processing
  • quality improvement
  • venous thromboembolism

Fingerprint

Dive into the research topics of 'Improved Identification of Venous Thromboembolism from Electronic Medical Records Using a Novel Information Extraction Software Platform'. Together they form a unique fingerprint.

Cite this