Skip to main navigation Skip to search Skip to main content

Improved temporal performance and optical quantum efficiency of avalanche amorphous selenium for low dose medical imaging

  • Corey Orlik
  • , Sébastien Levéillé
  • , Salman M. Arnab
  • , Adrian F. Howansky
  • , Jann Stavro
  • , Scott Dow
  • , Safa Kasap
  • , Kenkichi Tanioka
  • , Amir H. Goldan
  • , Wei Zhao
  • Stony Brook University
  • Analogic Canada Corporation
  • University of Saskatchewan

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

2 Scopus citations

Abstract

Active matrix flat panel imagers (AMFPIs) with thin-film transistor (TFT) arrays have become the dominant technology for digital x-ray imaging. However, their performance is degraded by electronic noise in low dose imaging applications. One potential solution is to overcome electronic noise using avalanche gain in an amorphous selenium (a-Se) photoconductor in indirect AMFPI, known as the scintillating high-gain avalanche rushing photoconductor AMFPI (SHARP-AMFPI). We previously developed two SHARP-AMFPI prototypes, however both have several areas of desired improvement. In this work, we fabricate and characterize HARP samples with a composite hole blocking layer (HBL) structure to reliably maintain avalanche fields while reducing temporal effects, as well as samples with tellurium (Te) alloyed a-Se to increase the optical quantum efficiency (OQE) to thallium doped cesium iodide (CsI:Tl) columnar scintillators. Our measurements show that the composite HBL has improved temporal performance over the original prototype, with ghosting below 3% at 10 mR equivalent exposure and no noticeable lag observed. We also show that the layer has comparable dark current to the previously used organic HBL and can reach an avalanche gain of 16. We aim to further reduce the dark current by improving the formulation of the n-type metal oxide layer using different deposition methods. Introducing Te-alloying to HARP samples shows an increase in OQE from 0.018 to 0.43 for 532 nm light. The addition of Te resulted in increased lag, attributed to charge trapping within the layer. Future work will investigate arsenic and chlorine co-doping to restore charge transport in this layer.

Original languageEnglish
Title of host publicationMedical Imaging 2022
Subtitle of host publicationPhysics of Medical Imaging
EditorsWei Zhao, Lifeng Yu
PublisherSPIE
ISBN (Electronic)9781510649378
DOIs
StatePublished - 2022
EventMedical Imaging 2022: Physics of Medical Imaging - Virtual, Online
Duration: Mar 21 2022Mar 27 2022

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume12031
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2022: Physics of Medical Imaging
CityVirtual, Online
Period03/21/2203/27/22

Keywords

  • Amorphous Selenium
  • Avalanche Gain
  • Flat Panel Imagers
  • Solid-State

Fingerprint

Dive into the research topics of 'Improved temporal performance and optical quantum efficiency of avalanche amorphous selenium for low dose medical imaging'. Together they form a unique fingerprint.

Cite this