In-situ photochemical fluorimetry of tyrosine and its determination

  • Weiping Cai
  • , Xisheng Wang
  • , Qingzhi Zhu
  • , Zhihong Wang
  • , Jingou Xu
  • Xiamen University

Research output: Contribution to journalArticlepeer-review

Abstract

Tyrosine can produce fluorescent dimers under irradiation with 275nm UV-light in NH3-NH4Cl buffer. Besed on this fact, a new photochemical fluorimetry in-situ was developed for determination of tyrosine. The linear relationship is over the range of 2.0 × 10-7 ∼ 2.0 × 10-5 mol/L tyrosine. The detection limit is 3.2 × 10-9 mol/L and relative standard deviation is 1.7%. This method is simple and rapid, and has better selectivity for other amino-acids. It has been applied to the determination of tyrosine in beer and amino-acid injections. Mechanism of the photochemical reaction was discussed.

Original languageEnglish
Pages (from-to)1537
Number of pages1
JournalFenxi Huaxue
Volume28
Issue number12
StatePublished - 2000

Keywords

  • Fluorimetry
  • Photochemical reaction
  • Tyrosine