Skip to main navigation Skip to search Skip to main content

Inhaled cyclosporine and pulmonary function in lung transplant recipients

  • Soleyah Groves
  • , Marek Galazka
  • , Bruce Johnson
  • , Timothy Corcoran
  • , Avelino Verceles
  • , Edward Britt
  • , Nevins Todd
  • , Bartley Griffith
  • , Gerald C. Smaldone
  • , Aldo Iacono
  • University of Maryland, Baltimore
  • University of Pittsburgh

Research output: Contribution to journalArticlepeer-review

43 Scopus citations

Abstract

Background: Chronic rejection, manifesting as bronchiolitis obliterans, is the leading cause of death in lung transplant recipients. In our previously reported double-blinded, placebo-controlled trial comparing inhaled cyclosporine (ACsA) to aerosol placebo, the rate of bronchiolitis-free survival improved. However, an independent analysis of pulmonary function, a secondary endpoint of the trial, was not performed. We sought to determine the effect of ACsA, in addition to systemic immunosuppression, on pulmonary function. Methods: From 1998-2001, 58 patients were randomly assigned to inhale either 300 mg of ACsA (28 patients) or placebo aerosol (30 patients) 3 days a week for the first 2 years after transplantation. Longitudinal changes in pulmonary function of ACsA patients were compared to aerosol placebo patients. In another analysis, the rate of decline from 6-month maximum FEV1 in randomized patients was compared to the rate of decline in patients receiving conventional immunosuppression from the Novartis transplant database (644 patients, 12 centers worldwide, transplanted from 1990-1995). Results: The average duration of ACsA and aerosol placebo was 400 days±306 and 433±256, respectively. The change in FEV1 of ACsA patients (adjusted for Cytomegalovirus (CMV) mismatch and transplant type, followed for a maximum duration of 4.6 years) was superior to the aerosol placebo controls (9.0±71.4mL/year vs. -107.9±55.3, p=0.007). The FEF 25-75 decreased by -220.3±117.7L/(second×year) vs. -412.2±139.2, p=0.07, respectively. Similarly, percent FEV1 decline from maximal values was improved in ACsA patients compared to aerosol placebo and Novartis controls (ACsA -0.43±1.12%/year vs. aerosol placebo -4.08±1.4, p=0.04; ACsA vs. Novartis -4.7±0.31, p=0.007). Single-lung recipients receiving ACsA showed improvement in FEV1 compared to Novartis controls (FEV1 -0.8±1.8%/year vs. -4.94±0.4, p=0.03) but double-lung recipients showed improvement compared to aerosol placebo controls only (FEV1 -0.28±1.22%/year vs. -8.53±5.95, p=0.048). Conclusions: In this single center trial, ACsA appears to ameliorate important pulmonary function parameters in lung transplant recipients compared to aerosol placebo and historical control patients. Single- and double-lung transplant recipients may not respond uniformly to treatment, and ongoing randomized trials in lung transplant recipients using ACsA may help elucidate our findings.

Original languageEnglish
Pages (from-to)31-39
Number of pages9
JournalJournal of Aerosol Medicine and Pulmonary Drug Delivery
Volume23
Issue number1
DOIs
StatePublished - Feb 1 2010

Keywords

  • Bronchiolitis obliterans
  • Chronic rejection
  • Inhaled cyclosporine
  • Lung transplant
  • Pulmonary function

Fingerprint

Dive into the research topics of 'Inhaled cyclosporine and pulmonary function in lung transplant recipients'. Together they form a unique fingerprint.

Cite this