Skip to main navigation Skip to search Skip to main content

Integrated MEMS structures and CMOS circuits for bioelectronic interface with single cells

  • N. Reeves
  • , Y. Liu
  • , N. M. Nelson
  • , S. Malhotra
  • , M. Loganathan
  • , J. M. Lauenstein
  • , J. Chaiyupatumpa
  • , E. Smela
  • , P. A. Abshire
  • University of Maryland, College Park

Research output: Contribution to journalConference articlepeer-review

23 Scopus citations

Abstract

We describe a bioMEMS system for confining and electrically interfacing to single cells for long-term studies. The system comprises microvials that can be covered and uncovered by lids actuated by polypyrrole/gold hinges. Within each vial are integrated bio-amplifiers and/or other sensing circuits to form a biolab-on-a-chip. We have developed a process sequence for fabricating lidded microvials with actuated lids on CMOS die. Initial testing of these "cell clinics" with bovine aortic smooth muscle cells yields successful sensing of the extracellular action potentials from bovine aortic smooth muscle cells using a custom VLSI bioamplifier.

Original languageEnglish
Pages (from-to)III673-III676
JournalProceedings - IEEE International Symposium on Circuits and Systems
Volume3
StatePublished - 2004
Event2004 IEEE International Symposium on Cirquits and Systems - Proceedings - Vancouver, BC, Canada
Duration: May 23 2004May 26 2004

Fingerprint

Dive into the research topics of 'Integrated MEMS structures and CMOS circuits for bioelectronic interface with single cells'. Together they form a unique fingerprint.

Cite this