Abstract
Free standing alumina-13% titania samples were manufactured using high power water stabilized plasma spraying. Heat treatment was performed at 1450°C for 24 hours and then at 1100°C for another 24 hours. Four point bend tests were performed on the as-sprayed and heat-treated samples in both cross section and in-plane orientations with in situ acoustic emission monitoring to monitor the cracking during the tests. Catastrophic failure with less evidence of microcracking was observed for as-sprayed samples. Energy and amplitude distributions were examined to discriminated micro- and macro-cracks. It was found that the high energy (> 100) and high amplitude (say > 60 dB) responses can be characterized as macro-cracks. Physical models are proposed to interpret the AE responses under different test conditions so that the cracking mechanisms can be better understood.
| Original language | English |
|---|---|
| Pages (from-to) | 261-266 |
| Number of pages | 6 |
| Journal | Materials Research Society Symposium - Proceedings |
| Volume | 409 |
| State | Published - 1996 |
| Event | Proceedings of the 1995 MRS Fall Symposium - Boston, MA, USA Duration: Nov 27 1995 → Nov 30 1995 |
Fingerprint
Dive into the research topics of 'Investigation of cracking mechanisms of plasma sprayed alumina-13% titania by acoustic emission'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver