Skip to main navigation Skip to search Skip to main content

Investigation of spatial-frequency-dependent noise in columnar CsI:Tl using depth-localized single x-ray imaging

  • Adrian Howansky
  • , A. R. Lubinsky
  • , Wei Zhao
  • Stony Brook University

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

3 Scopus citations

Abstract

The x-ray imaging performance of an indirect flat panel detector (I-FPD) is intrinsically limited by its scintillator. Random fluctuations in the conversion gain and spatial blur of scintillators (per detected x-ray) degrade the detective quantum efficiency (DQE) of I-FPDs. These variations are often attributed to depth-dependence in light escape efficiency and spatial spread before detection. Past investigations have used theoretical models to explore how scintillator depth effects degrade DQE(f), however such models have not been validated by direct measurements. Recently, experimental methods have been developed to localize the depth of x-ray interactions in a scintillator, and image the light burst from each interaction using an ultra-high-sensitivity optical camera. This approach, referred to as depth-localized single x-ray imaging (SXI), has enabled direct measurements of both depth-dependent and fixed-depth variations in scintillator gain and spatial resolution. SXI has been used recently to measure depth-dependence in the average gain and modulation transfer function (MTF) of columnar CsI:Tl, which is the scintillator-of-choice for medical I-FPDs. When used in a depth-dependent cascaded linear system model, these SXI measurements accurately predict the presampling MTF(f) of CsI:Tl-based I-FPDs as measured using the slanted-edge method. However, such calculations underestimate the CsI:Tl noise power spectrum (NPS), and thereby overestimate its DQE when compared to conventional measurements. We hypothesize that some of this discrepancy is caused by fixed-depth variations in CsI:Tl spatial resolution, which are not considered in current models. This work characterizes these variations directly using depth-localized SXI and examines their impact on scintillator DQE(f).

Original languageEnglish
Title of host publicationMedical Imaging 2019
Subtitle of host publicationPhysics of Medical Imaging
EditorsTaly Gilat Schmidt, Guang-Hong Chen, Hilde Bosmans
PublisherSPIE
ISBN (Electronic)9781510625433
DOIs
StatePublished - 2019
EventMedical Imaging 2019: Physics of Medical Imaging - San Diego, United States
Duration: Feb 17 2019Feb 20 2019

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume10948
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2019: Physics of Medical Imaging
Country/TerritoryUnited States
CitySan Diego
Period02/17/1902/20/19

Keywords

  • Cesium iodide
  • Detective quantum efficiency
  • Digital radiography
  • Flat panel detector
  • Lubberts effect
  • Noise power spectrum
  • Scintillator
  • Synchrotron

Fingerprint

Dive into the research topics of 'Investigation of spatial-frequency-dependent noise in columnar CsI:Tl using depth-localized single x-ray imaging'. Together they form a unique fingerprint.

Cite this