TY - GEN
T1 - Investigation on analytical methods for correction of distance-dependent resolution variation in 3D SPECT imaging
AU - Li, Jian
AU - Liang, Zhengrong
AU - Ye, Jinghan
AU - Han, Guoping
PY - 1999
Y1 - 1999
N2 - Spatial resolution variation as a function of distance from collimator surface in single photon emission computed tomography (SPECT) is a major obstacle for quantitative imaging. This work investigated two analytical inversion methods for correcting the distance-dependent resolution variation. The first one derives accurately an inversion formula, but approximates the resolution variation kernel. The second one considers accurately the resolution variation kernel, but approximates the inversion formula. Reconstructed images using the first method showed a better resolution recovery at the central area of field-of-view (FOV), consistent with the approach that the resolution kernel is approximated for near-field regions. The second method restored resolution better at the FOV periphery, consistent with the theory that the formula is approximated for farfield regions. The first method is very sensitive to the approximation. The second one is robust and, therefore, is a better choice for quantitative SPECT imaging.
AB - Spatial resolution variation as a function of distance from collimator surface in single photon emission computed tomography (SPECT) is a major obstacle for quantitative imaging. This work investigated two analytical inversion methods for correcting the distance-dependent resolution variation. The first one derives accurately an inversion formula, but approximates the resolution variation kernel. The second one considers accurately the resolution variation kernel, but approximates the inversion formula. Reconstructed images using the first method showed a better resolution recovery at the central area of field-of-view (FOV), consistent with the approach that the resolution kernel is approximated for near-field regions. The second method restored resolution better at the FOV periphery, consistent with the theory that the formula is approximated for farfield regions. The first method is very sensitive to the approximation. The second one is robust and, therefore, is a better choice for quantitative SPECT imaging.
UR - https://www.scopus.com/pages/publications/0032596927
M3 - Conference contribution
AN - SCOPUS:0032596927
SN - 0780350227
T3 - IEEE Nuclear Science Symposium and Medical Imaging Conference
SP - 1620
EP - 1624
BT - IEEE Nuclear Science Symposium and Medical Imaging Conference
PB - IEEE
T2 - Proceedings of the 1998 IEEE Nuclear Science Symposium Conference Record
Y2 - 8 November 1998 through 14 November 1998
ER -