Skip to main navigation Skip to search Skip to main content

Low-dose CT reconstruction with MRF prior predicted from patch samples of normal-dose CT database

  • Junyan Rong
  • , Yuanke Zhang
  • , Yuxiang Xing
  • , Peng Gao
  • , Tianshuai Liu
  • , Zhengrong Liang
  • , Hongbing Lu
  • Air Force Medical University
  • Tsinghua University

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

Abstract

Markov random field (MRF) model-based penalty is widely used in statistical iterative reconstruction (SIR) of low dose CT (LDCT) reconstruction for noise suppression and edge-preserving. In this strategy, normal dose CT scans are usually used as a priori information to further improve the LDCT quality. However, repeated CT scans are needed and registration or segmentation is usually applied first when misalignment between the low-dose and normal-dose scans exists. The study aims to propose a new MRF prior model of SIR based on the NDCT database without registration. In the proposed model, MRF weights are predicted using optimal similar patch samples from the NDCT database. The patch samples are determined by evaluating the similarity with Euclidean distance between patches from NDCT and the target patch of LDCT. The proposed prior term is incorporated into the SIR cost function, which is to be minimized for LDCT reconstruction. The proposed method is tested on an artificial LDCT data based on a high-dose patient data. Preliminary result has proved its potential performance in edge and structure detail preservation.

Original languageEnglish
Title of host publicationMedical Imaging 2018
Subtitle of host publicationPhysics of Medical Imaging
EditorsTaly Gilat Schmidt, Guang-Hong Chen, Joseph Y. Lo
PublisherSPIE
ISBN (Electronic)9781510616356
DOIs
StatePublished - 2018
EventMedical Imaging 2018: Physics of Medical Imaging - Houston, United States
Duration: Feb 12 2018Feb 15 2018

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume10573
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2018: Physics of Medical Imaging
Country/TerritoryUnited States
CityHouston
Period02/12/1802/15/18

Keywords

  • CT database
  • Low dose CT reconstruction
  • MRF prior
  • normal-dose CT

Fingerprint

Dive into the research topics of 'Low-dose CT reconstruction with MRF prior predicted from patch samples of normal-dose CT database'. Together they form a unique fingerprint.

Cite this