TY - GEN
T1 - Low-Rank Continual Pyramid Vision Transformer
T2 - 27th International Conference on Medical Image Computing and Computer-Assisted Intervention, MICCAI 2024
AU - Zhu, Vince
AU - Ji, Zhanghexuan
AU - Guo, Dazhou
AU - Wang, Puyang
AU - Xia, Yingda
AU - Lu, Le
AU - Ye, Xianghua
AU - Zhu, Wei
AU - Jin, Dakai
N1 - Publisher Copyright:
© The Author(s), under exclusive license to Springer Nature Switzerland AG 2024.
PY - 2024
Y1 - 2024
N2 - Deep segmentation networks achieve high performance when trained on specific datasets. However, in clinical practice, it is often desirable that pretrained segmentation models can be dynamically extended to enable segmenting new organs without access to previous training datasets or without training from scratch. This would ensure a much more efficient model development and deployment paradigm accounting for the patient privacy and data storage issues. This clinically preferred process can be viewed as a continual semantic segmentation (CSS) problem. Previous CSS works would either experience catastrophic forgetting or lead to unaffordable memory costs as models expand. In this work, we propose a new continual whole-body organ segmentation model with light-weighted low-rank adaptation (LoRA). We first train and freeze a pyramid vision transformer (PVT) base segmentation model on the initial task, then continually add light-weighted trainable LoRA parameters to the frozen model for each new learning task. Through a holistically exploration of the architecture modification, we identify three most important layers (i.e., patch-embedding, multi-head attention and feed forward layers) that are critical in adapting to the new segmentation tasks, while retaining the majority of the pre-trained parameters fixed. Our proposed model continually segments new organs without catastrophic forgetting and meanwhile maintaining a low parameter increasing rate. Continually trained and tested on four datasets covering different body parts of a total of 121 organs, results show that our model achieves high segmentation accuracy, closely reaching the PVT and nnUNet upper bounds, and significantly outperforms other regularization-based CSS methods. When comparing to the leading architecture-based CSS method, our model has a substantial lower parameter increasing rate (16.7% versus 96.7%) while achieving comparable performance.
AB - Deep segmentation networks achieve high performance when trained on specific datasets. However, in clinical practice, it is often desirable that pretrained segmentation models can be dynamically extended to enable segmenting new organs without access to previous training datasets or without training from scratch. This would ensure a much more efficient model development and deployment paradigm accounting for the patient privacy and data storage issues. This clinically preferred process can be viewed as a continual semantic segmentation (CSS) problem. Previous CSS works would either experience catastrophic forgetting or lead to unaffordable memory costs as models expand. In this work, we propose a new continual whole-body organ segmentation model with light-weighted low-rank adaptation (LoRA). We first train and freeze a pyramid vision transformer (PVT) base segmentation model on the initial task, then continually add light-weighted trainable LoRA parameters to the frozen model for each new learning task. Through a holistically exploration of the architecture modification, we identify three most important layers (i.e., patch-embedding, multi-head attention and feed forward layers) that are critical in adapting to the new segmentation tasks, while retaining the majority of the pre-trained parameters fixed. Our proposed model continually segments new organs without catastrophic forgetting and meanwhile maintaining a low parameter increasing rate. Continually trained and tested on four datasets covering different body parts of a total of 121 organs, results show that our model achieves high segmentation accuracy, closely reaching the PVT and nnUNet upper bounds, and significantly outperforms other regularization-based CSS methods. When comparing to the leading architecture-based CSS method, our model has a substantial lower parameter increasing rate (16.7% versus 96.7%) while achieving comparable performance.
UR - https://www.scopus.com/pages/publications/85206933647
U2 - 10.1007/978-3-031-72111-3_35
DO - 10.1007/978-3-031-72111-3_35
M3 - Conference contribution
AN - SCOPUS:85206933647
SN - 9783031721106
T3 - Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics)
SP - 371
EP - 381
BT - Medical Image Computing and Computer Assisted Intervention – MICCAI 2024 - 27th International Conference, Proceedings
A2 - Linguraru, Marius George
A2 - Dou, Qi
A2 - Feragen, Aasa
A2 - Giannarou, Stamatia
A2 - Glocker, Ben
A2 - Lekadir, Karim
A2 - Schnabel, Julia A.
PB - Springer Science and Business Media Deutschland GmbH
Y2 - 6 October 2024 through 10 October 2024
ER -