Abstract
The dark matter time projection chamber (DMTPC) is a direction-sensitive detector designed to measure the direction of recoiling F19 and C12 nuclei in low-pressure CF4 gas using optical and charge readout systems. In this paper, we employ measurements from two DMTPC detectors, with operating pressures of 30-60 torr, to develop and validate a model of the directional response and performance of such detectors as a function of recoil energy. Using our model as a benchmark, we formulate the necessary specifications for a scalable directional detector with sensitivity comparable to that of current-generation counting (nondirectional) experiments, which measure only recoil energy. Assuming the performance of existing DMTPC detectors, as well as current limits on the spin-dependent WIMP-nucleus cross section, we find that a 10-20 kg scale direction-sensitive detector is capable of correlating the measured direction of nuclear recoils with the predicted direction of incident dark matter particles and providing decisive (3σ) confirmation that a candidate signal from a nondirectional experiment was indeed induced by elastic scattering of dark matter particles off of target nuclei.
| Original language | English |
|---|---|
| Journal | Physical Review D |
| Volume | 95 |
| Issue number | 12 |
| DOIs | |
| State | Published - Jun 15 2017 |
Fingerprint
Dive into the research topics of 'Measurement of the directional sensitivity of Dark Matter Time Projection Chamber detectors'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver