Skip to main navigation Skip to search Skip to main content

Micro-computed tomography of primate molars: Methodological aspects of three-dimensional data collection

  • Max Planck Institute for Evolutionary Anthropology

Research output: Chapter in Book/Report/Conference proceedingChapterpeer-review

15 Scopus citations

Abstract

Phylogenetic, paleodietary, and developmental studies of hominoid primates frequently make use of the post-canine dentition, in particular molar teeth. To study the thickness and shape of molar enamel and dentine, internal dental structures must be revealed (e.g., the location of dentine horn apices), typically necessitating the production of physical sections through teeth. The partially destructive nature of such studies limits sample sizes and access to valuable fossil specimens, which has led scholars to apply several methods of radiographic visualization to the study of teeth. Radiographic methods aimed at visualizing internal dental structures include lateral flat-plane X-rays, ultrasound, terra-hertz imaging, and computed tomography. Each of these techniques has resolution limitations rendering them inadequate for accurately reconstructing both the enamel-dentine junction and the outer enamel surface; the majority of studies are thus performed using physical sections of teeth. A comparatively new imaging technique, micro-computed tomography (mCT), accurately portrays the enamel-dentine junction of primate molars, and provides accurate measurements of enamel cap thickness and morphology. The research presented here describes methodological parameters pertinent to mCT studies of molars (slice thickness and pixel resolution), and the observable impact on measurement accuracy when these parameters are altered. Measurements taken on a small, taxonomically diverse sample of primate molars indicate that slice thickness should be conservatively set at approximately 3.45 % of specimen length, and image resolution should be maximized (ideally, greater than or equal to 2048 × 2048 pixels per image) in order to ensure measurement accuracy. After discussing this base-line protocol for future mCT studies of the primate dentition, illustrative applications of this imaging technology are presented.

Original languageEnglish
Title of host publicationVertebrate Paleobiology and Paleoanthropology
PublisherSpringer
Pages103-115
Number of pages13
Edition9781402058448
DOIs
StatePublished - 2007

Publication series

NameVertebrate Paleobiology and Paleoanthropology
Number9781402058448
ISSN (Print)1877-9077

Keywords

  • 3-D rendering
  • Image resolution
  • mCT
  • Measurement accuracy
  • Molar enamel volume
  • Molars
  • Pixels
  • Slice thickness
  • Three-dimensional measurements
  • Voxels

Fingerprint

Dive into the research topics of 'Micro-computed tomography of primate molars: Methodological aspects of three-dimensional data collection'. Together they form a unique fingerprint.

Cite this