Skip to main navigation Skip to search Skip to main content

Multicentre dose-ranging study on the efficacy of USPIO ferumoxtran-10 for liver MR imaging

  • S. Saini
  • , R. Sharma
  • , R. L. Baron
  • , D. A. Turner
  • , P. R. Ros
  • , P. F. Hahn
  • , W. C. Small
  • , E. E. Delange
  • , A. E. Stillman
  • , R. R. Edelman
  • , V. M. Runge
  • , E. K. Outwater
  • Departments of Radiology
  • Harvard University
  • University of Pittsburgh
  • Rush University Medical Center
  • Emory University
  • University of Virginia
  • University of Minnesota Twin Cities
  • University of Kentucky
  • Thomas Jefferson University

Research output: Contribution to journal › Article › peer-review

39 Scopus citations

Abstract

Aim: A dose ranging multicentre phase-II clinical trial was conducted to evaluate the efficacy of ultrasmall superparamagnetic iron oxide (USPIO) ferumoxtran-10 for magnetic resonance (MR) imaging of focal hepatic lesions. Material and Methods: Ninety-nine patients with focal liver lesions received USPIO at a dose of 0.8 (n = 35), 1.1 (n = 32), or 1.7 (n = 32) mg Fe/kg. Liver MR imaging was performed before and after USPIO with T1-weighted and T2-weighted pulse sequences. Images were analysed by two independent readers for additional information (lesion detection, exclusion, characterization and patient management). Signal intensity (SI) based quantitative measurements were also taken. Results: Post-contrast medium MR imaging showed additional information in 71/97 patients (73%) for reader one and 83/96 patients (86%) for reader two. The results with all three doses were statistically significant (P<0.05). Signal intensity analysis revealed that all three doses increased liver SI on T1-weighted images and decreased liver SI on T2-weighted images. On T2-weighted images metastases increased in contrast relative to normal hepatic parenchyma whereas haemangiomas decreased in contrast. On T2-weighted images there was statistically improved efficacy at the intermediate dose, which did not improve at the highest dose. Conclusion: Ultrasmall superparamagnetic iron oxide was an effective contrast agent for liver MR imaging at all doses and a dose of 1.1 mg Fe/kg was recommended for future clinical trials.

Original languageEnglish
Pages (from-to)690-695
Number of pages6
JournalClinical Radiology
Volume55
Issue number9
DOIs
StatePublished - 2000

Keywords

  • Contrast media
  • Liver
  • MR imaging

Fingerprint

Dive into the research topics of 'Multicentre dose-ranging study on the efficacy of USPIO ferumoxtran-10 for liver MR imaging'. Together they form a unique fingerprint.

Cite this