Skip to main navigation Skip to search Skip to main content

Multidrug Aerosol Delivery During Mechanical Ventilation

  • Stony Brook University

Research output: Contribution to journalArticlepeer-review

2 Scopus citations

Abstract

Background: In the critically ill, pulmonary vasodilators are often provided off label to intubated patients using continuous nebulization. If additional aerosol therapies such as bronchodilators or antibiotics are needed, vasodilator therapy may be interrupted. This study assesses aerosol systems designed for simultaneous delivery of two aerosols using continuous nebulization and bolus injection without interruption or circuit disconnection. Methods: One i-AIRE dual-port breath-enhanced jet nebulizer (BEJN) or two Aerogen Solo vibrating mesh nebulizers (VMNs) were installed on the dry side of the humidifier. VMN were stacked; one for infusion and the second for bolus drug delivery. The BEJN was powered by air at 3.5 L/min, 50 psig. Radiolabeled saline was infused at 5 and 10 mL/h with radiolabeled 3 and 6 mL bolus injections at 30 and 120 minutes, respectively. Two adult breathing patterns (duty cycle 0.13 and 0.34) were tested with an infusion time of 4 hours. Inhaled mass (IM) expressed as % of initial syringe activity (IM%/min) was monitored in real time with a ratemeter. All delivered radioaerosol was collected on a filter at the airway opening. Transients in aerosol delivery were measured by calibrated ratemeter. Results: IM%/h during continuous infusion was linear and predictable, mean – standard deviation (SD): 2.12 – 1.45%/h, 2.47 – 0.863%/h for BEJN and VMN, respectively. BEJN functioned without incident. VMN continuous aerosol delivery stopped spontaneously in 3 of 8 runs (38%); bolus delivery stopped spontaneously in 3 of 16 runs (19%). Tapping restarted VMN function during continuous and bolus delivery runs. Bolus delivery IM% (mean – SD): 20.90% – 7.01%, 30.40% – 11.10% for BEJN and VMN, respectively. Conclusion: Simultaneous continuous and bolus nebulization without circuit disconnection is possible for both jet and mesh technology. Monitoring of VMN devices may be necessary in case of spontaneous interruption of nebulization.

Original languageEnglish
Pages (from-to)154-161
Number of pages8
JournalJournal of Aerosol Medicine and Pulmonary Drug Delivery
Volume36
Issue number4
DOIs
StatePublished - Aug 1 2023

Keywords

  • administration
  • aerosols
  • drug delivery
  • inhalation
  • mechanical
  • nebulizers and vaporizers
  • ventilators

Fingerprint

Dive into the research topics of 'Multidrug Aerosol Delivery During Mechanical Ventilation'. Together they form a unique fingerprint.

Cite this