Skip to main navigation Skip to search Skip to main content

Noninvasive determination of the optical properties of adult brain: Near-infrared spectroscopy approach

  • Jee Hyun Choi
  • , Martin Wolf
  • , Vladislav Toronov
  • , Ursula Wolf
  • , Chiara Polzonetti
  • , Dennis Hueber
  • , Larisa P. Safonova
  • , Rajarsi Gupta
  • , Antonios Michalos
  • , William Mantulin
  • , Enrico Gratton
  • University of Illinois at Urbana-Champaign
  • ISS

Research output: Contribution to journalArticlepeer-review

201 Scopus citations

Abstract

The basic parameters for physiological measurements provided by near-infrared spectroscopy are the local absorption and scattering coefficients. For the adult human head, they have been difficult to measure noninvasively because of the layered structure of the head. The results of measurements of absorption and reduced scattering coefficients through the forehead on 30 adult volunteers using a multi-distance frequency domain method are reported. The optode separation distance ranged from 10 to 80 mm and measurements were recorded at 758 and 830 nm. The measured absorption and reduced scattering coefficients of the forehead were used to evaluate the hemoglobin content in the scalp and brain as well as cerebral oxygen saturation. We found that cerebral oxygenation was relatively narrowly distributed within the subject group (the standard deviation was about 3% for scalp and 6% for brain, respectively), whereas hemoglobin concentrations had a relatively broader distribution. We found that as the optode distance increased, the absorption coefficients increased and the scattering coefficients decreased, retrieving the optical values of scalp and brain for shorter and longer optode distances, respectively. We present the transition curves of the absorption and reduced scattering coefficients as functions of the optode distance. In order to verify the values for each layer, a comparison between the experimental data and a prediction based on the two-layer model of the adult head was carried out. The thicknesses of scalp and skull for the two-layer model were obtained by magnetic resonance imaging of a subject's head. The optical parameters obtained from the two-layer model agreed very well with those measured by the multidistance method.

Original languageEnglish
Pages (from-to)221-229
Number of pages9
JournalJournal of Biomedical Optics
Volume9
Issue number1
DOIs
StatePublished - Jan 2004

Keywords

  • Brain perfusion
  • Frequency domain
  • Near-infrared

Fingerprint

Dive into the research topics of 'Noninvasive determination of the optical properties of adult brain: Near-infrared spectroscopy approach'. Together they form a unique fingerprint.

Cite this