TY - GEN
T1 - Optimizing data center energy efficiency via ambient-aware IT workload scheduling
AU - Kumari, Niru
AU - Shah, Amip
AU - Bash, Cullen
AU - Chen, Yuan
AU - Liu, Zhenhua
AU - Wang, Zhikui
AU - Cader, Tahir
AU - Slaby, Matt
AU - Cepulis, Darren
AU - Felix, Carlos
AU - Aviles, Abdiel
AU - Figueroa, Miguel
PY - 2012
Y1 - 2012
N2 - Energy consumption in data centers has increased over the years. A significant percentage of the total energy required by data centers may be consumed by cooling equipment. To decrease cooling cost, incorporation of air-side economization, or "free" cooling, which utilizes locally available outside air to augment or replace the cooling capacity provided by traditional data center cooling infrastructure, has been explored in recent years. However, little work has been done on exploiting the diurnal nature of outside air conditions by integrating the active management of cooling and IT workload scheduling. In this paper, we estimate the savings obtained by using this concept of integrated management in a containerized data center that implements a micro-grid of cooling resources consisting of outside air, conditioned air using DX (Direct Expansion) units, and a combination of both. For such a data center, a previously developed energy model is utilized to estimate the annual savings obtained by scheduling workload according to the variable cost of cooling resource generation and delivery. The impact of data center location and allowable IT inlet air temperature range on savings is also studied. The results show that the integrated management can decrease the cooling cost by up to 50% depending on location of the data center, the types of IT workload and total IT resources available in the data center.
AB - Energy consumption in data centers has increased over the years. A significant percentage of the total energy required by data centers may be consumed by cooling equipment. To decrease cooling cost, incorporation of air-side economization, or "free" cooling, which utilizes locally available outside air to augment or replace the cooling capacity provided by traditional data center cooling infrastructure, has been explored in recent years. However, little work has been done on exploiting the diurnal nature of outside air conditions by integrating the active management of cooling and IT workload scheduling. In this paper, we estimate the savings obtained by using this concept of integrated management in a containerized data center that implements a micro-grid of cooling resources consisting of outside air, conditioned air using DX (Direct Expansion) units, and a combination of both. For such a data center, a previously developed energy model is utilized to estimate the annual savings obtained by scheduling workload according to the variable cost of cooling resource generation and delivery. The impact of data center location and allowable IT inlet air temperature range on savings is also studied. The results show that the integrated management can decrease the cooling cost by up to 50% depending on location of the data center, the types of IT workload and total IT resources available in the data center.
KW - cooling microgrid
KW - data center
KW - energy efficiency
KW - integrated cooling
KW - workload management
UR - https://www.scopus.com/pages/publications/84866161091
U2 - 10.1109/ITHERM.2012.6231477
DO - 10.1109/ITHERM.2012.6231477
M3 - Conference contribution
AN - SCOPUS:84866161091
SN - 9781424495320
T3 - InterSociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems, ITHERM
SP - 539
EP - 544
BT - Proceedings of the 13th InterSociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems, ITherm 2012
T2 - 13th InterSociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems, ITherm 2012
Y2 - 30 May 2012 through 1 June 2012
ER -