Partial volume correction for arterial spin labeling data using spatial-temporal information

  • Yang Liu
  • , Baojuan Li
  • , Xi Zhang
  • , Linchuan Zhang
  • , Zhengrong Liang
  • , Hongbing Lu
  • Air Force Medical University

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

1 Scopus citations

Abstract

Arterial spin labeling (ASL) provides a noninvasive measurement of cerebral blood flow (CBF). Due to relatively low spatial resolution, the accuracy of CBF measurement is affected by the partial volume (PV) effect. In general ASL sequence, multiple scans of perfusion image pairs are acquired temporally to improve the signal to noise ratio. Several spatial PV correction methods have been proposed for the simple averaging of pair-difference images, while the perfusion information of gray matter and white matter existed in multiple image pairs was totally ignored. In this study, a statistical model of perfusion mixtures inside each voxel for the 4D ASL sequence is first proposed. To solve the model, a simplified method is proposed, in which the linear regression (LR) method is first used to obtain initial estimates of spatial correction, then an EM (expectation maximization) method is used to obtain accurate estimation using temporal information. The combination of LR and EM method (EM-LR) can effectively utilize the spatial-temporal information of ASL data for PV correction and provide a theoretical solution to estimate the perfusion mixtures. Both simulated and in vivo data were used to evaluate the performance of proposed method, which demonstrated its superiority on PV correction, edge preserving, and noise suppression.

Original languageEnglish
Title of host publicationMedical Imaging 2015
Subtitle of host publicationImage Processing
EditorsMartin A. Styner, Sebastien Ourselin
PublisherSPIE
ISBN (Electronic)9781628415032
DOIs
StatePublished - 2015
EventMedical Imaging 2015: Image Processing - Orlando, United States
Duration: Feb 24 2015Feb 26 2015

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume9413
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2015: Image Processing
Country/TerritoryUnited States
CityOrlando
Period02/24/1502/26/15

Keywords

  • arterial spin labeling
  • cerebral blood flow
  • expectation maximization
  • partial volume effect
  • perfusion

Fingerprint

Dive into the research topics of 'Partial volume correction for arterial spin labeling data using spatial-temporal information'. Together they form a unique fingerprint.

Cite this