TY - GEN
T1 - Quantitative wavelet domain image processing of dynamic PET data
AU - Erlandsson, Kjell
AU - Jin, Yinpeng
AU - Wong, Andrew T.
AU - Esser, Peter D.
AU - Laine, Andrew F.
AU - Ogden, R. Todd
AU - Oquendo, Maria A.
AU - Van Heertum, Ronald
AU - Mann, J. John
AU - Parsey, Ramin V.
PY - 2006
Y1 - 2006
N2 - Neuroreceptor PET studies consisting of long dynamic data acquisitions result in data with low signal-to-noise ratio and limited spatial resolution. To address these problems we have developed a 3D wavelet-based image processing tool (wavelet filter, WF), containing both denoising and enhancement functionality. The filter is based on multi-scale thresholding and cross-scale regularization. These operations are data-driven, which may lead to non-linearity effects and hamper quantification of dynamic PET data. The aim of the present study was to investigate these effects using both phantom and human PET data. A phantom study was performed with a cylindrical phantom, filled with 18F, containing a number of spherical inserts filled with 11C. Human studies were performed on 9 healthy volunteers after injection of the serotonine transporter tracer [11C]DASB. Images from both phantom and human studies were reconstructed with filtered backprojection and post-processed by WF with a series of different denoising and enhancement parameter values. The phantom study was analyzed by computing the insert-to-background ratio as a function of time. The human study was analyzed with a 1-tissue compartment model for a series of brain regions. For the phantom study, linear relations were found between unprocessed and WF processed data for positive contrasts. However, for negative contrast, non-linearity effects were observed. For the human data, good correlation was obtained between results from unprocessed and WF processed data. Our results showed that, although non-linear effects may appear in low-contrast areas, it is possible to achieve accurate quantification with wavelet-based image processing.
AB - Neuroreceptor PET studies consisting of long dynamic data acquisitions result in data with low signal-to-noise ratio and limited spatial resolution. To address these problems we have developed a 3D wavelet-based image processing tool (wavelet filter, WF), containing both denoising and enhancement functionality. The filter is based on multi-scale thresholding and cross-scale regularization. These operations are data-driven, which may lead to non-linearity effects and hamper quantification of dynamic PET data. The aim of the present study was to investigate these effects using both phantom and human PET data. A phantom study was performed with a cylindrical phantom, filled with 18F, containing a number of spherical inserts filled with 11C. Human studies were performed on 9 healthy volunteers after injection of the serotonine transporter tracer [11C]DASB. Images from both phantom and human studies were reconstructed with filtered backprojection and post-processed by WF with a series of different denoising and enhancement parameter values. The phantom study was analyzed by computing the insert-to-background ratio as a function of time. The human study was analyzed with a 1-tissue compartment model for a series of brain regions. For the phantom study, linear relations were found between unprocessed and WF processed data for positive contrasts. However, for negative contrast, non-linearity effects were observed. For the human data, good correlation was obtained between results from unprocessed and WF processed data. Our results showed that, although non-linear effects may appear in low-contrast areas, it is possible to achieve accurate quantification with wavelet-based image processing.
UR - https://www.scopus.com/pages/publications/34047117975
U2 - 10.1109/IEMBS.2006.259525
DO - 10.1109/IEMBS.2006.259525
M3 - Conference contribution
C2 - 17946981
AN - SCOPUS:34047117975
SN - 1424400325
SN - 9781424400324
T3 - Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings
SP - 2787
EP - 2790
BT - 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'06
T2 - 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'06
Y2 - 30 August 2006 through 3 September 2006
ER -