Skip to main navigation Skip to search Skip to main content

Randomized Trial of Aspirin Versus Warfarin After Transcatheter Aortic Valve Replacement in Low-Risk Patients

  • Toby Rogers
  • , Christian Shults
  • , Rebecca Torguson
  • , Corey Shea
  • , Puja Parikh
  • , Thomas Bilfinger
  • , Thomas Cocke
  • , Mariano E. Brizzio
  • , Robert Levitt
  • , Chiwon Hahn
  • , Nicholas Hanna
  • , George Comas
  • , Paul Mahoney
  • , Joseph Newton
  • , Maurice Buchbinder
  • , Ricardo Moreno
  • , Cheng Zhang
  • , Paige Craig
  • , Federico M. Asch
  • , Gaby Weissman
  • Hector M. Garcia-Garcia, Itsik Ben-Dor, Lowell F. Satler, Ron Waksman
  • Washington Hospital Center
  • National Institutes of Health
  • Valley Hospital
  • Hca Virginia Health System
  • St. John Health System
  • Sentara Healthcare
  • Foundation for Cardiovascular Medicine
  • University of California at San Diego

Research output: Contribution to journalArticlepeer-review

53 Scopus citations

Abstract

Background: The optimal antithrombotic regimen after transcatheter aortic valve replacement remains unclear. Methods: In this randomized open-label study, low-risk patients undergoing transfemoral transcatheter aortic valve replacement at 7 centers in the United States were randomized 1:1 to low-dose aspirin or warfarin plus low-dose aspirin for 30 days. Patients who could not be randomized were enrolled in a separate registry. Computed tomography or transesophageal echocardiography was performed at 30 days. The primary effectiveness end point was a composite of the following at 30 days: hypoattenuated leaflet thickening, at least moderately reduced leaflet motion, hemodynamic dysfunction (mean aortic valve gradient ≥20 mm Hg, effective orifice area ≤1.0 cm2, dimensionless valve index <0.35, or moderate or severe aortic regurgitation), stroke, or transient ischemic attack. Results: Between July 2018 and October 2019, 94 patients were randomly assigned, 50 to aspirin and 44 to warfarin plus aspirin, and 30 were enrolled into the registry. In the intention-to-treat analysis of the randomized cohort, the composite primary effectiveness end point was met in 26.5% for aspirin versus 7.0% for warfarin plus aspirin (P=0.014; odds ratio, 4.8 [95% CI, 1.3-18.3]). The rate of hypoattenuated leaflet thickening was 16.3% for aspirin versus 4.7% for warfarin plus aspirin (P=0.07; odds ratio, 4.0 [95% CI, 0.8-20.0]). There was no excess bleeding at 30 days with anticoagulation. In the as-treated analysis of pooled randomized and registry cohorts, the rate of hypoattenuated leaflet thickening was 16.7% for aspirin versus 3.1% for warfarin plus aspirin (P=0.011; odds ratio, 6.3 [95% CI, 1.3-30.6]). Conclusions: In low-risk transcatheter aortic valve replacement patients, anticoagulation with warfarin may prevent transcatheter heart valve dysfunction in the short term without excess bleeding. Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT03557242.

Original languageEnglish
Pages (from-to)E009983
JournalCirculation: Cardiovascular Interventions
Volume14
Issue number1
DOIs
StatePublished - Jan 1 2021

Keywords

  • anticoagulants
  • aortic valve stenosis
  • aspirin
  • transcatheter aortic valve replacement
  • warfarin

Fingerprint

Dive into the research topics of 'Randomized Trial of Aspirin Versus Warfarin After Transcatheter Aortic Valve Replacement in Low-Risk Patients'. Together they form a unique fingerprint.

Cite this