TY - JOUR
T1 - Randomized Trial of Aspirin Versus Warfarin After Transcatheter Aortic Valve Replacement in Low-Risk Patients
AU - Rogers, Toby
AU - Shults, Christian
AU - Torguson, Rebecca
AU - Shea, Corey
AU - Parikh, Puja
AU - Bilfinger, Thomas
AU - Cocke, Thomas
AU - Brizzio, Mariano E.
AU - Levitt, Robert
AU - Hahn, Chiwon
AU - Hanna, Nicholas
AU - Comas, George
AU - Mahoney, Paul
AU - Newton, Joseph
AU - Buchbinder, Maurice
AU - Moreno, Ricardo
AU - Zhang, Cheng
AU - Craig, Paige
AU - Asch, Federico M.
AU - Weissman, Gaby
AU - Garcia-Garcia, Hector M.
AU - Ben-Dor, Itsik
AU - Satler, Lowell F.
AU - Waksman, Ron
N1 - Publisher Copyright:
© 2021 Lippincott Williams and Wilkins. All rights reserved.
PY - 2021/1/1
Y1 - 2021/1/1
N2 - Background: The optimal antithrombotic regimen after transcatheter aortic valve replacement remains unclear. Methods: In this randomized open-label study, low-risk patients undergoing transfemoral transcatheter aortic valve replacement at 7 centers in the United States were randomized 1:1 to low-dose aspirin or warfarin plus low-dose aspirin for 30 days. Patients who could not be randomized were enrolled in a separate registry. Computed tomography or transesophageal echocardiography was performed at 30 days. The primary effectiveness end point was a composite of the following at 30 days: hypoattenuated leaflet thickening, at least moderately reduced leaflet motion, hemodynamic dysfunction (mean aortic valve gradient ≥20 mm Hg, effective orifice area ≤1.0 cm2, dimensionless valve index <0.35, or moderate or severe aortic regurgitation), stroke, or transient ischemic attack. Results: Between July 2018 and October 2019, 94 patients were randomly assigned, 50 to aspirin and 44 to warfarin plus aspirin, and 30 were enrolled into the registry. In the intention-to-treat analysis of the randomized cohort, the composite primary effectiveness end point was met in 26.5% for aspirin versus 7.0% for warfarin plus aspirin (P=0.014; odds ratio, 4.8 [95% CI, 1.3-18.3]). The rate of hypoattenuated leaflet thickening was 16.3% for aspirin versus 4.7% for warfarin plus aspirin (P=0.07; odds ratio, 4.0 [95% CI, 0.8-20.0]). There was no excess bleeding at 30 days with anticoagulation. In the as-treated analysis of pooled randomized and registry cohorts, the rate of hypoattenuated leaflet thickening was 16.7% for aspirin versus 3.1% for warfarin plus aspirin (P=0.011; odds ratio, 6.3 [95% CI, 1.3-30.6]). Conclusions: In low-risk transcatheter aortic valve replacement patients, anticoagulation with warfarin may prevent transcatheter heart valve dysfunction in the short term without excess bleeding. Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT03557242.
AB - Background: The optimal antithrombotic regimen after transcatheter aortic valve replacement remains unclear. Methods: In this randomized open-label study, low-risk patients undergoing transfemoral transcatheter aortic valve replacement at 7 centers in the United States were randomized 1:1 to low-dose aspirin or warfarin plus low-dose aspirin for 30 days. Patients who could not be randomized were enrolled in a separate registry. Computed tomography or transesophageal echocardiography was performed at 30 days. The primary effectiveness end point was a composite of the following at 30 days: hypoattenuated leaflet thickening, at least moderately reduced leaflet motion, hemodynamic dysfunction (mean aortic valve gradient ≥20 mm Hg, effective orifice area ≤1.0 cm2, dimensionless valve index <0.35, or moderate or severe aortic regurgitation), stroke, or transient ischemic attack. Results: Between July 2018 and October 2019, 94 patients were randomly assigned, 50 to aspirin and 44 to warfarin plus aspirin, and 30 were enrolled into the registry. In the intention-to-treat analysis of the randomized cohort, the composite primary effectiveness end point was met in 26.5% for aspirin versus 7.0% for warfarin plus aspirin (P=0.014; odds ratio, 4.8 [95% CI, 1.3-18.3]). The rate of hypoattenuated leaflet thickening was 16.3% for aspirin versus 4.7% for warfarin plus aspirin (P=0.07; odds ratio, 4.0 [95% CI, 0.8-20.0]). There was no excess bleeding at 30 days with anticoagulation. In the as-treated analysis of pooled randomized and registry cohorts, the rate of hypoattenuated leaflet thickening was 16.7% for aspirin versus 3.1% for warfarin plus aspirin (P=0.011; odds ratio, 6.3 [95% CI, 1.3-30.6]). Conclusions: In low-risk transcatheter aortic valve replacement patients, anticoagulation with warfarin may prevent transcatheter heart valve dysfunction in the short term without excess bleeding. Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT03557242.
KW - anticoagulants
KW - aortic valve stenosis
KW - aspirin
KW - transcatheter aortic valve replacement
KW - warfarin
UR - https://www.scopus.com/pages/publications/85100279957
U2 - 10.1161/CIRCINTERVENTIONS.120.009983
DO - 10.1161/CIRCINTERVENTIONS.120.009983
M3 - Article
C2 - 33423540
AN - SCOPUS:85100279957
SN - 1941-7640
VL - 14
SP - E009983
JO - Circulation: Cardiovascular Interventions
JF - Circulation: Cardiovascular Interventions
IS - 1
ER -