Skip to main navigation Skip to search Skip to main content

Refining the IceCube detector geometry using muon and LED calibration data

  • The IceCube Collaboration
  • Loyola University Chicago
  • German Electron Synchrotron
  • University of Canterbury
  • University of Wisconsin-Madison
  • Institute of Physics Bhubaneswar
  • Université libre de Bruxelles
  • University of Copenhagen
  • TU Dortmund University
  • University of Delaware
  • Marquette University
  • Friedrich-Alexander University Erlangen-Nürnberg
  • Harvard University
  • University of Utah
  • South Dakota School of Mines & Technology
  • University of California at Irvine
  • University of California at Berkeley
  • Ohio State University
  • Ruhr University Bochum
  • Chalmers University of Technology
  • Uppsala University
  • Technical University of Munich
  • RWTH Aachen University
  • University of Rochester
  • University of Maryland, College Park
  • University of Padua
  • University of Kansas
  • Karlsruhe Institute of Technology
  • Johannes Gutenberg University Mainz
  • Georgia Institute of Technology
  • University of Adelaide
  • University of Münster
  • Drexel University

Research output: Contribution to journalConference articlepeer-review

Abstract

The IceCube Neutrino Observatory deployed 5160 digital optical modules (DOMs) on 86 cables, called strings, in a cubic kilometer of deep glacial ice below the geographic South Pole. These record the Cherenkov light of passing charged particles. Knowledge of the DOM positions is vital for event reconstruction. While vertical positions have been calibrated, previous in-situ geometry calibration methods have been unable to measure horizontal deviations from the surface positions, largely due to degeneracies with ice model uncertainties. Thus the lateral position of the surface position of each hole is to date in almost all cases used as the lateral position of all DOMs on a given string. With the recent advances in ice modeling, two new in-situ measurements have now been undertaken. Using a large sample of muon tracks, the individual positions of all DOMs on a small number of strings around the center of the detector have been fitted. Verifying the results against LED calibration data shows that the string-average corrections improve detector modeling. Directly fitting string-average geometry corrections for the full array using LED data agrees with the average corrections as derived from muons where available. Analyses are now ongoing to obtain per-DOM positions using both methods and in addition, methods are being developed to correct the recorded arrival times for the expected scattering delay, allowing for multilateration of the positions using nanosecond-precision propagation delays.

Original languageEnglish
Article number988
JournalProceedings of Science
Volume444
StatePublished - Sep 27 2024
Event38th International Cosmic Ray Conference, ICRC 2023 - Nagoya, Japan
Duration: Jul 26 2023Aug 3 2023

Fingerprint

Dive into the research topics of 'Refining the IceCube detector geometry using muon and LED calibration data'. Together they form a unique fingerprint.

Cite this