TY - GEN
T1 - Segmentation of Overlapped Steatosis in Whole-Slide Liver Histopathology Microscopy Images
AU - Roy, Mousumi
AU - Wang, Fusheng
AU - Teodoro, George
AU - Vos, Miriam B.
AU - Farris, Alton Brad
AU - Kong, Jun
N1 - Publisher Copyright:
© 2018 IEEE.
PY - 2018/10/26
Y1 - 2018/10/26
N2 - An accurate steatosis quantification with pathology tissue samples is of high clinical importance. However, such pathology measurement is manually made in most clinical practices, subject to severe reader variability due to large sampling bias and poor reproducibility. Although some computerized automated methods are developed to quantity the steatosis regions, they present limited analysis capacity for high resolution whole-slide microscopy images and accurate overlapped steatosis division. In this paper, we propose a method that extracts an individual whole tissue piece at high resolution with minimum background area by estimating tissue bounding box and rotation angle. This is followed by the segmentation and segregation of steatosis regions with high curvature point detection and an ellipse fitting quality assessment method. We validate our method with isolated and overlapped steatosis regions in liver tissue images of 11 patients. The experimental results suggest that our method is promising for enhanced support of steatosis quantization during the pathology review for liver disease treatment.
AB - An accurate steatosis quantification with pathology tissue samples is of high clinical importance. However, such pathology measurement is manually made in most clinical practices, subject to severe reader variability due to large sampling bias and poor reproducibility. Although some computerized automated methods are developed to quantity the steatosis regions, they present limited analysis capacity for high resolution whole-slide microscopy images and accurate overlapped steatosis division. In this paper, we propose a method that extracts an individual whole tissue piece at high resolution with minimum background area by estimating tissue bounding box and rotation angle. This is followed by the segmentation and segregation of steatosis regions with high curvature point detection and an ellipse fitting quality assessment method. We validate our method with isolated and overlapped steatosis regions in liver tissue images of 11 patients. The experimental results suggest that our method is promising for enhanced support of steatosis quantization during the pathology review for liver disease treatment.
UR - https://www.scopus.com/pages/publications/85056637602
U2 - 10.1109/EMBC.2018.8512289
DO - 10.1109/EMBC.2018.8512289
M3 - Conference contribution
C2 - 30440516
AN - SCOPUS:85056637602
T3 - Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS
SP - 810
EP - 813
BT - 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2018
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2018
Y2 - 18 July 2018 through 21 July 2018
ER -