Abstract

Recent studies have shown that the Bruch's membrane (BM) and retinal pigment epithelium (RPE), visualized on spectral-domain optical coherence tomography (SD-OCT), is deformed anteriorly towards the vitreous in patients with intracranial hypertension and papilledema. The BM/RPE shape has been quantified using a statistical-shape-model approach; however, to date, the approach has involved the tedious and time-consuming manual placement of landmarks and correspondingly, only the shape (and shape changes) of a limited number of patients has been studied. In this work, we first present a semi-automated approach for the extraction of 20 landmarks along the BM from an optic-nerve-head (ONH) centered OCT slice from each patient. In the approach, after the manual placement of the two Bruch's membrane opening (BMO) points, the remaining 18 landmarks are automatically determined using a graph-based segmentation approach. We apply the approach to the OCT scans of 116 patients (at baseline) enrolled in the Idiopathic Intracranial Hypertension Treatment Trial and generate a statistical shape model using principal components analysis. Using the resulting shape model, the coefficient (shape measure) corresponding to the second principal component (eigenvector) for each set of landmarks indicates the degree of the BM/RPE is oriented away from the vitreous. Using a subset of 20 patients, we compare the shape measure computed using this semi-automated approach with the resulting shape measure when (1) all landmarks are specified manually (Experiment I); and (2) a different expert specifies the two BMO points (Experiment II). In each case, a correlation coefficient ≥ 0.99 is obtained.

Original languageEnglish
Title of host publicationMedical Imaging 2015
Subtitle of host publicationBiomedical Applications in Molecular, Structural, and Functional Imaging
EditorsBarjor Gimi, Robert C. Molthen
PublisherSPIE
ISBN (Electronic)9781628415070
DOIs
StatePublished - 2015
EventMedical Imaging 2015: Biomedical Applications in Molecular, Structural, and Functional Imaging - Orlando, United States
Duration: Feb 24 2015Feb 26 2015

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume9417
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2015: Biomedical Applications in Molecular, Structural, and Functional Imaging
Country/TerritoryUnited States
CityOrlando
Period02/24/1502/26/15

Keywords

  • Bruch's membrane
  • Optical coherence tomography
  • Papilledema
  • Shape analysis

Fingerprint

Dive into the research topics of 'Semi-automated 2D Bruch's membrane shape analysis in papilledema using spectral-domain optical coherence tomography'. Together they form a unique fingerprint.

Cite this