Superparamagnetic iron oxide particles (SH U 555 A): Evaluation of efficacy in three doses for hepatic MR imaging

  • Kohkan Shamsi
  • , Thomas Balzer
  • , Sanjay Saini
  • , Pablo R. Ros
  • , Rendon C. Nelson
  • , Eric C. Carter
  • , Susan Tollerfield
  • , Hans Peter Niendorf
  • Bayer AG
  • Massachusetts General Hospital
  • Duke University
  • Schering Health Care

Research output: Contribution to journalArticlepeer-review

62 Scopus citations

Abstract

PURPOSE: To evaluate the efficacy of SH U 555 A in three doses for magnetic resonance (MR) imaging in the liver and to establish the best postinjection time point for liver MR imaging. MATERIALS AND METHODS: Pre- and postcontrast image sets obtained in 169 patients after injection of SH U 555 A (randomly, 4, 8, or 16 μmol of iron per kilogram of body weight). Three blinded readers evaluated the precontrast and 10- and 40-minute postcontrast MR images of 54, 58, and 57 patients, respectively. RESULTS: Statistically significant differences were observed in diagnostic confidence between images obtained with a dose of 4 or 16 μmol Fe/Kg (P = .011) and in good or excellent improvement, respectively, in delineation of lesions on 10- minute postcontrast images (P = .001). No apparent differences in the efficacy evaluation were seen between the 10- and 40-minute postcontrast imaging time points. CONCLUSION: There was a dose-dependent postcontrast improvement in evaluated efficacy parameters (diagnostic confidence, visual evaluations) after injection of SH U 555 A. Accumulation phase imaging could begin as early as 10 minutes after administration.

Original languageEnglish
Pages (from-to)365-371
Number of pages7
JournalRadiology
Volume206
Issue number2
DOIs
StatePublished - Feb 1998

Keywords

  • Iron
  • Liver neoplasms, MR
  • Liver, MR
  • Magnetic resonance (MR), contrast enhancement