TY - GEN
T1 - Texture-based CAD improves diagnosis for low-dose CT colonography
AU - Liang, Zhengrong
AU - Cohen, Harris
AU - Posniak, Erica
AU - Fiore, Eddie
AU - Wang, Zigang
AU - Li, Bin
AU - Andersen, Joseph
AU - Harrington, Donald
PY - 2008
Y1 - 2008
N2 - Computed tomography (CT)-based virtual colonoscopy or CT colonography (CTC) currently utilizes oral contrast solutions to tag the colonic fluid and possibly residual stool for differentiation from the colon wall and polyps. The enhanced image density of the tagged colonic materials causes a significant partial volume (PV) effect into the colon wall as well as the lumen space (filled with air or CO2). The PV effect on the colon wall can "bury" polyps of size as large as 5mm by increasing their image densities to a noticeable level, resulting in false negatives. It can also create false positives when PV effect goes into the lumen space. We have been modeling the PV effect for mixture-based image segmentation and developing text-based computer-aided detection of polyp (CADpolyp) by utilizing the PV mixture-based image segmentation. This work presents some preliminary results of developing and applying texture-based CADpolyp technique to low-dose CTC studies. A total of 114 studies of asymptomatic patients older than 50, who underwent CTC and then optical colonoscopy (OC) on the same day, were selected from a database, which was accumulated in the past decade and contains various bowel preparations and CT scanning protocols. The participating radiologists found ten polyps of greater than 5 mm from a total of 16 OC proved polyps, i.e., a detection sensitivity of 63%. They scored 23 false positives from the database, i.e., a 20% false positive rate. Approximately 70% of the datasets were marked as imperfect bowel cleansing and/or presence of image artifacts. The impact of imperfect bowel cleansing and image artifacts on VC performance is significant. The texture-based CADpolyp detected all the polyps with an average of 2.68 false positives per patient. This indicates that texture-based CADpolyp can improve the CTC performance in the cases of imperfect cleansed bowels and presence of image artifacts.
AB - Computed tomography (CT)-based virtual colonoscopy or CT colonography (CTC) currently utilizes oral contrast solutions to tag the colonic fluid and possibly residual stool for differentiation from the colon wall and polyps. The enhanced image density of the tagged colonic materials causes a significant partial volume (PV) effect into the colon wall as well as the lumen space (filled with air or CO2). The PV effect on the colon wall can "bury" polyps of size as large as 5mm by increasing their image densities to a noticeable level, resulting in false negatives. It can also create false positives when PV effect goes into the lumen space. We have been modeling the PV effect for mixture-based image segmentation and developing text-based computer-aided detection of polyp (CADpolyp) by utilizing the PV mixture-based image segmentation. This work presents some preliminary results of developing and applying texture-based CADpolyp technique to low-dose CTC studies. A total of 114 studies of asymptomatic patients older than 50, who underwent CTC and then optical colonoscopy (OC) on the same day, were selected from a database, which was accumulated in the past decade and contains various bowel preparations and CT scanning protocols. The participating radiologists found ten polyps of greater than 5 mm from a total of 16 OC proved polyps, i.e., a detection sensitivity of 63%. They scored 23 false positives from the database, i.e., a 20% false positive rate. Approximately 70% of the datasets were marked as imperfect bowel cleansing and/or presence of image artifacts. The impact of imperfect bowel cleansing and image artifacts on VC performance is significant. The texture-based CADpolyp detected all the polyps with an average of 2.68 false positives per patient. This indicates that texture-based CADpolyp can improve the CTC performance in the cases of imperfect cleansed bowels and presence of image artifacts.
KW - Colonic material tagging
KW - CTC
KW - PV image segmentation
KW - Texture based CADpolyp
KW - Tissue mixture modeling
UR - https://www.scopus.com/pages/publications/44349151684
U2 - 10.1117/12.768073
DO - 10.1117/12.768073
M3 - Conference contribution
AN - SCOPUS:44349151684
SN - 9780819471000
T3 - Progress in Biomedical Optics and Imaging - Proceedings of SPIE
BT - Medical Imaging 2008 - Physiology, Function, and Structure from Medical Images
T2 - Medical Imaging 2008 - Physiology, Function, and Structure from Medical Images
Y2 - 17 February 2008 through 19 February 2008
ER -