Skip to main navigation Skip to search Skip to main content

The Fate of Elevated Metal Ion Levels After Revision Surgery for Head-Neck Taper Corrosion in Patients With Metal-on-Polyethylene Total Hip Arthroplasty

  • Young Min Kwon
  • , John MacAuliffe
  • , Yun Peng
  • , Paul Arauz
  • Massachusetts General Hospital

Research output: Contribution to journalArticlepeer-review

15 Scopus citations

Abstract

Background: Elevated metal ion levels have been associated with the presence of adverse local tissue reactions in patients with metal-on-polyethylene (MoP) total hip arthroplasty (THA) secondary to corrosion at head-neck taper junction. Patients are frequently concerned with their elevated systemic metal ion levels. This study investigated the rate of decline of serum cobalt and chromium ion levels after revision surgery. Methods: A total of 39 patients with MoP THA were revised because of the presence of symptomatic adverse local tissue reactions on magnetic resonance imaging with elevated serum metal ion levels. The time between initial implantation of MoP THA (index surgery) and revision surgery was considered the duration of metal exposure. The prerevision measure of ion level was considered the intensity of exposure. Prerevision median serum Co and Cr levels, as well as revision serum Co/Cr ratio, were reported. Results: The median serum levels of cobalt and cobalt-to-chromium ratio significantly decreased from prerevision levels of 8.2 μg/L (0.2-56.1 μg/L) and 5.6 μg/L (0.1-53.3 μg/L) to 3.1 μg/L (0.2-14 μg/L) and 1.7 μg/L (0.4-3.8 μg/L) at postrevision (P <.01), respectively. The rate of decline of Co was 0.45% per day during the first month. For chromium, the rate of decline was slower with 0.08% per day during the first month. Conclusion: At 3 months after revision surgery, cobalt and chromium ion levels declined by 34% and 8% of prerevision level, respectively. This study provides evidence-based practical information for surgeons to provide MoP THA patients when considering revision surgery for head-neck taper corrosion.

Original languageEnglish
Pages (from-to)2631-2635
Number of pages5
JournalJournal of Arthroplasty
Volume33
Issue number8
DOIs
StatePublished - Aug 2018

Keywords

  • adverse local tissue reaction
  • cobalt and chromium metal ion level
  • head-neck taper corrosion
  • metal ion levels decline
  • metal-on-polyethylene total hip arthroplasty

Fingerprint

Dive into the research topics of 'The Fate of Elevated Metal Ion Levels After Revision Surgery for Head-Neck Taper Corrosion in Patients With Metal-on-Polyethylene Total Hip Arthroplasty'. Together they form a unique fingerprint.

Cite this